{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LTMR08MFM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LTMR08MFM","canonicalUrl":"https://aoctrl.com/schneider/LTMR08MFM","factsUrl":"https://aoctrl.com/api/mcp/products/LTMR08MFM","rawCanonicalId":null},"summary":{"shortDescription":"Motor controller, TeSys T, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC|Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.8 in (122.5 mm)","Range":"TeSys","Width":"3.6 in (91 mm)","Height":"2.4 in (61 mm)","Bus type":"Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs","Category":"US10I1222338","Standards":"IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14","Load current":"5 A 250 V AC logic output 5 A 30 V DC logic output","Product name":"TeSys T","Web services":"Web server","Input current":"3.1 mA 100 V 7.5 mA 240 V","Metering type":"Average current Iavg Temperature Earth-fault current Imbalance current Phase current I1, I2, I3 RMS","Fire resistance":"1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94","Protection Type":"Reverse polarity protection Locked rotor Earth-leakage protection Thermal overload protection Phase failure Overload Thermal protection Power factor variation Load fluctuation Phase unbalance Overload (long time)","lifecycle_stage":"unknown","Connection pitch":"0.20 in (5.08 mm)","Pollution degree":"3","Device short name":"LTMR","Permissible power":"480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)","Tightening torque":"Control circuit: 4.4...5.3 lbf.in (0.5...0.6 N.m) flat screwdriver 0.1 in (3 mm)","Compatibility code":"LTMR","Device Application":"Equipment monitoring and control","Logic input number":"6","Operating altitude":"<= 6561.68 ft (2000 m) without derating","Current Consumption":"8...62.8 mA","Measurement current":"0.4...8 A","Measurement accuracy":"5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power","Overvoltage category":"III","Protective treatment":"12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068","Mechanical robustness":"Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27","Nbr. of units in pkg.":"1","Supply voltage limits":"93.5...264 V AC","Associated fuse rating":"4 A gG output 0.5 A gG control circuit","Maximum Operating Rate":"1800 cyc/h","Connections - terminals":"Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008...0.002 in² (0.5...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)solid without cable end","IP Degree of Protection":"IP20","Short-circuit withstand":"100 kA conforming to EN/IEC 60947-4-1","Product or Component Type":"Motor controller","[Us] rated supply voltage":"100...240 V AC 50/60 Hz","Current state 0 guaranteed":"Logic input 0...40 V <= 15 mA 25 ms","Current state 1 guaranteed":"Logic input 79...264 V >= 2 mA 25 ms","Communication Port Protocol":"Modbus","Contacts type and composition":"1 NO + 1 NC fault signal 3 NO","Electromagnetic compatibility":"Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5","[Ui] rated insulation voltage":"690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508","Maximum Output Switching Frequency":"2 Hz","Network and machine diagnosis type":"Event recording Fault recording Waiting time after overload tripping Running hours counter/operating time Phase fault and earth fault trip counters Trip context information Starting current and time Motor control command recording Remaining operating time before overload tripping Trip history information","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$267.56","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8fa94353738416f4ea7a1afd445a5649.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LTMR08MFM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LTMR08MFM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LTMR08MFM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}