{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCA32BL","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCA32BL","canonicalUrl":"https://aoctrl.com/schneider/LUCA32BL","factsUrl":"https://aoctrl.com/api/mcp/products/LUCA32BL","rawCanonicalId":null},"summary":{"shortDescription":"STD.CNTRL.UNIT-CL10-3PH 8-32A 24VDC|STD.CNTRL.UNIT-CL10-3PH 8-32A 24VDC","salesMarkdown":null,"metaTitle":"LUCA32BL","metaDescription":"STD.CNTRL.UNIT-CL10-3PH 8-32A 24VDC|STD.CNTRL.UNIT-CL10-3PH 8-32A 24VDC","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.4 in (60 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"2.6 in (66 mm)","Category":"US10I1122397","Load type":"3-phase motor self-cooled","Standards":"EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier","Fixing mode":"Plug-in (front face)","Product name":"TeSys Ultra","Motor power kW":"15 kW 400...440 V AC 50/60 Hz 15 kW 500 V AC 50/60 Hz 18.5 kW 690 V AC 50/60 Hz","Operating time":"35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit","Fire resistance":"1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12","lifecycle_stage":"current","Heat dissipation":"3 W control circuit with LUB32 3 W control circuit with LUB38","Range of Product":"TeSys Ultra","Shock resistance":"10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27","Device short name":"LUCA","Network frequency":"40...60 Hz","Compatibility code":"LUCA","Device Application":"Motor control Motor protection","Operating altitude":"6561.68 ft (2000 m)","Tripping threshold":"14.2 x Ir +/- 20 %","Protective treatment":"TH IEC 60068","Utilisation category":"AC-43 AC-44 AC-41","Vibration resistance":"2 gn 5...300 Hz power poles open IEC 60068-2-6 4 gn 5...300 Hz power poles closed IEC 60068-2-6","Nbr. of units in pkg.":"1","Thermal overload class":"Class 10 40...60 Hz -13...158 °F (-25...70 °C) IEC 60947-6-2 Class 10 40...60 Hz -13...158 °F (-25...70 °C) UL 508","IP degree of protection":"IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1","Immunity to microbreaks":"3 ms","Main Function Available":"Earth fault protection Protection against overload and short-circuit Manual reset Protection against phase failure and phase imbalance","Immunity to voltage dips":"70 % / 500 ms IEC 61000-4-11","Phase failure sensitivity":"Yes","Product or Component Type":"Standard control unit","Safe separation of circuit":"400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1","Typical current consumption":"220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38","Product Specific Application":"Basic protection requirements for motor starters: overload and short-circuit","[Uc] control circuit voltage":"24 V DC","Resistance to fast transients":"2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4","Resistance to radiated fields":"9.1 V/m (10 V/m) 3 IEC 61000-4-3","[Ui] rated insulation voltage":"690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1","Control circuit voltage limits":"20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out","[Ue] rated operational voltage":"690 V AC","Immunity to radioelectric fields":"10 V IEC 61000-4-6","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Rated Motor Current Adjustment Range":"8...32 A","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","Resistance to electrostatic discharge":"8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-6-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$81.28 – $209.98","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/125955609a99798f6e1bd418df5e8aed.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCA32BL/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCA32BL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCA32BL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}