{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCA32FUTQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCA32FUTQ","canonicalUrl":"https://aoctrl.com/schneider/LUCA32FUTQ","factsUrl":"https://aoctrl.com/api/mcp/products/LUCA32FUTQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys U standard control unit LUCA32FUTQ, 15 kW at 400-440 V AC, control circuit 110-240 V AC / 110-220 V DC, IP20 front panel.","salesMarkdown":"The Schneider Electric LUCA32FUTQ is a standard control unit in the TeSys U motor starter range, designed for basic protection of 3-phase motors — overload and short-circuit protection with manual reset, plus earth fault and phase failure/ imbalance detection. Rated for motor power up to 15 kW at 400-440 V AC (50/60 Hz), 15 kW at 500 V, and 18.5 kW at 690 V, it covers a wide band of standard low-voltage industrial motors. The control circuit accepts 110-240 V AC or 110-220 V DC, with dropout at 55 V for either supply — a useful margin for brownout ride-through on a line. The LUCA32FUTQ carries utilisation categories AC-41, AC-43, and AC-44 per IEC 60947-6-2. AC-41 covers resistive loads; AC-43 and AC-44 cover motor starting and switching under normal and occasional overload conditions — so this unit is qualified for the full motor-starting duty cycle, not just steady-state protection. Thermal overload class 10 per IEC 60947-6-2, with temperature compensation from -25 to 70 °C.","metaTitle":"Schneider Electric LUCA32FUTQ TeSys U Control Unit, 15 kW","metaDescription":"LUCA32FUTQ TeSys U standard control unit. 15 kW at 400 V AC, 110-240 V AC / 110-220 V DC coil. Current lifecycle, sourced to order. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"60 mm","Range":"TeSys","Width":"45 mm","Height":"66 mm","Load type":"3-phase motor - cooling: self-cooled","Standards":"EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier","Fixing mode":"Plug-in (front face)","Product name":"TeSys U","Motor power kW":"15 kW at 400...440 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz","Operating time":"35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 50 ms closing with LUB32 for control circuit 50 ms closing with LUB38 for control circuit","Fire resistance":"960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12","lifecycle_stage":"current","Heat dissipation":"3 W for control circuit with LUB32 3 W for control circuit with LUB38","Range of product":"TeSys U","Shock resistance":"10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27","Device short name":"LUCA","Network frequency":"40...60 Hz","Compatibility code":"LUCA","Device application":"Motor control Motor protection","Operating altitude":"2000 m","Tripping threshold":"14.2 x Ir +/- 20 %","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-43 AC-41 AC-44","Vibration resistance":"2 gn, 5...300 Hz, power poles open conforming to IEC 60068-2-6 4 gn, 5...300 Hz, power poles closed conforming to IEC 60068-2-6","Thermal overload class":"Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C conforming to IEC 60947-6-2 Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C conforming to UL 508","IP degree of protection":"IP20 front panel and wired terminals conforming to IEC 60947-1 IP20 other faces conforming to IEC 60947-1 IP40 front panel outside connection zone conforming to IEC 60947-1","Immunity to microbreaks":"3 ms","Main Function Available":"Earth fault protection Protection against overload and short-circuit Manual reset Protection against phase failure and phase imbalance","Immunity to voltage dips":"70 % / 500 ms conforming to IEC 61000-4-11","Phase failure sensitivity":"Yes","Product or component type":"Standard control unit","Non-dissipating shock wave":"1 kV serial mode conforming to IEC 60947-6-2 2 kV common mode conforming to IEC 60947-6-2","Safe separation of circuit":"400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1","Typical current consumption":"280 mA at 110...240 V AC I maximum while closing with LUB32 280 mA at 110...240 V AC I maximum while closing with LUB38 280 mA at 110...220 V DC I maximum while closing with LUB32 280 mA at 110...220 V DC I maximum while closing with LUB38 25 mA at 110...240 V AC I rms sealed with LUB32 25 mA at 110...240 V AC I rms sealed with LUB38 25 mA at 110...220 V DC I rms sealed with LUB32 25 mA at 110...220 V DC I rms sealed with LUB38","Product specific application":"Basic protection requirements for motor starters: overload and short-circuit","[Uc] control circuit voltage":"110...220 V DC 110...240 V AC","Resistance to fast transients":"2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4","Resistance to radiated fields":"10 V/m 3 conforming to IEC 61000-4-3","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1","Control circuit voltage limits":"88...264 V for AC circuit 110...240 V in operation 88...242 V for DC circuit 110...220 V in operation 55 V for AC circuit 110...240 V drop-out 55 V for DC circuit 110...220 V drop-out","[Ue] rated operational voltage":"690 V AC","Immunity to radioelectric fields":"10 V conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...85 °C","Rated Motor Current Adjustment Range":"8...32 A","Ambient air temperature for operation":"-25...70 °C","Resistance to electrostatic discharge":"8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-6-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/LUCA32FUTQ/standard-control-unit-tesys-u-832a-3p-motors-thermal-magnetic-protection-class-10-coil-110240v-ac-dc-tq10/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCA32FUTQ/alternatives.json"},"ai":{"faq":[{"question":"What are the specifications of LUCA32FUTQ?","answer":"Key specs: motor power 15 kW at 400-440 V AC (50/60 Hz), control voltage 110-240 V AC / 110-220 V DC, thermal overload class 10, utilisation categories AC-41/AC-43/AC-44, IP20 front panel, dimensions 45 x 66 x 60 mm (W x H x D)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCA32FUTQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCA32FUTQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}