{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCB32FU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCB32FU","canonicalUrl":"https://aoctrl.com/schneider/LUCB32FU","factsUrl":"https://aoctrl.com/api/mcp/products/LUCB32FU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys Ultra advanced control unit LUCB32FU, manual reset, 110...240 V AC / 110...220 V DC control voltage, plug-in front face, depth 2.4 in (60 mm).","salesMarkdown":"## LUCB32FU – Manual reset, motor protection control unit The Schneider LUCB32FU is an advanced control unit from the TeSys Ultra range designed for motor protection and control with a manual reset mechanism. It operates with a control circuit voltage of 110...240 V AC or 110...220 V DC, drawing 280 mA while closing and 25 mA sealed. The unit plugs into the TeSys Ultra contactor base via a front-face plug-in fixing mode, allowing quick replacement without disturbing the power wiring. Physical footprint: 1.8 in (45 mm) wide, 2.6 in (66 mm) tall, 2.4 in (60 mm) deep. Front panel protection IP20; other faces IP20. ## Mounting and environmental ratings The LUCB32FU is rated for operating altitudes up to 2000 m, with thermal overload class 10 covering 40...60 Hz and ambient -25...70 °C. Heat dissipation is 3 W with the matching LUB32 or LUB38 control circuit. It withstands shock of 10 gn with poles open and 15 gn with poles closed, and vibration of 2 gn (open) or 4 gn (closed) across 5–300 Hz. ## Standards and certifications The control unit complies with EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No 60947-4-1 with phase barrier. Fire resistance: parts supporting live components withstand 960 °C, others 650 °C per IEC 60695-2-12.","metaTitle":"Schneider LUCB32FU TeSys Ultra Control Unit, Manual Reset","metaDescription":"Schneider LUCB32FU advanced control unit for TeSys Ultra. Manual reset, 110-240 VAC/DC control, plug-in mount, IP20. Current production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.4 in (60 mm)","Range":"TeSys","Reset":"Manual reset","Width":"1.8 in (45 mm)","Height":"2.6 in (66 mm)","Category":"US10I1122397","Load type":"3-phase motor self-cooled","Standards":"EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier","Fixing mode":"Plug-in (front face)","Product name":"TeSys Ultra","Motor power kW":"15 kW 400...440 V AC 50/60 Hz 15 kW 500 V AC 50/60 Hz 18.5 kW 690 V AC 50/60 Hz","Operating time":"35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 50 ms closing with LUB32 control circuit 50 ms closing with LUB38 control circuit","Fire resistance":"1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12","lifecycle_stage":"current","Heat dissipation":"3 W control circuit with LUB32 3 W control circuit with LUB38","Range of Product":"TeSys Ultra","Shock resistance":"10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27","Device short name":"LUCB","Network frequency":"40...60 Hz","Compatibility code":"LUCB","Device Application":"Motor control Motor protection","Operating altitude":"6561.68 ft (2000 m)","Tripping threshold":"14.2 x Ir +/- 20 %","Protective treatment":"TH IEC 60068","Utilisation category":"AC-44 AC-43 AC-41","Vibration resistance":"2 gn 5...300 Hz power poles open IEC 60068-2-6 4 gn 5...300 Hz power poles closed IEC 60068-2-6","Nbr. of units in pkg.":"1","Thermal overload class":"Class 10 40...60 Hz -13...158 °F (-25...70 °C) IEC 60947-6-2 Class 10 40...60 Hz -13...158 °F (-25...70 °C) UL 508","IP degree of protection":"IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1","Immunity to microbreaks":"3 ms","Main Function Available":"Manual reset Protection against overload and short-circuit Earth fault protection Protection against phase failure and phase imbalance","Immunity to voltage dips":"70 % / 500 ms IEC 61000-4-11","Phase failure sensitivity":"Yes","Product or Component Type":"Advanced control unit","Non-dissipating shock wave":"1 kV serial mode IEC 60947-6-2 2 kV common mode IEC 60947-6-2","Safe separation of circuit":"400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1","Typical current consumption":"280 mA 110...240 V AC I maximum while closing with LUB32 280 mA 110...240 V AC I maximum while closing with LUB38 280 mA 110...220 V DC I maximum while closing with LUB32 280 mA 110...220 V DC I maximum while closing with LUB38 25 mA 110...240 V AC I rms sealed with LUB32 25 mA 110...240 V AC I rms sealed with LUB38 25 mA 110...220 V DC I rms sealed with LUB32 25 mA 110...220 V DC I rms sealed with LUB38","Product Specific Application":"Basic protection and advanced functions, communication","[Uc] control circuit voltage":"110...240 V AC 110...220 V DC","Resistance to fast transients":"2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4","Resistance to radiated fields":"9.1 V/m (10 V/m) 3 IEC 61000-4-3","[Ui] rated insulation voltage":"690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1","Control circuit voltage limits":"88...264 V AC 110...240 V in operation 88...242 V DC 110...220 V in operation 55 V AC 110...240 V drop-out 55 V DC 110...220 V drop-out","[Ue] rated operational voltage":"690 V AC","Immunity to radioelectric fields":"10 V IEC 61000-4-6","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Rated Motor Current Adjustment Range":"8...32 A","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","Resistance to electrostatic discharge":"8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-6-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$102.87 – $185.91","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/44a81d54c9af028339f6d7e452898c3c.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCB32FU/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the LUCB32FU?","answer":"The depth is 2.4 inches (60 mm)."},{"question":"What range does the LUCB32FU belong to?","answer":"It is part of the Schneider TeSys Ultra range."},{"question":"What compliance documentation does the LUCB32FU meet?","answer":"It complies with EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No 60947-4-1 with phase barrier."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCB32FU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCB32FU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}