{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCC05BL","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCC05BL","canonicalUrl":"https://aoctrl.com/schneider/LUCC05BL","factsUrl":"https://aoctrl.com/api/mcp/products/LUCC05BL","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Ultra LUCC05BL, advanced control unit for single-phase motor protection, 0.55 kW at 400...440 V AC, 24 V DC control, manual reset.","salesMarkdown":"## TeSys Ultra Control Unit – Key Ratings The Schneider Electric TeSys Ultra LUCC05BL is an advanced control unit for motor protection, sized for single-phase motors up to 0.55 kW at 400...440 V AC, 50/60 Hz. It operates on 24 V DC control and provides manual reset, thermal class 10 protection, and utilization categories AC-43, AC-41, AC-44. ## Mounting & Wiring Notes Mounts plug-in (front face) to the TeSys Ultra base. Dimensions: 2.4 in depth, 1.8 in width, 2.6 in height. IP20 protection front panel, IP40 other faces outside connection zone. Operating time: 35 ms opening, 70 ms closing with LUB control circuits. Heat dissipation 2–3 W depending on control circuit. Complies with IEC 60947-6-2, UL 60947-4-1, CSA C22.2 No 60947-4-1 with phase barrier. Rated insulation voltage 690 V IEC, 600 V UL/CSA.","metaTitle":"Schneider LUCC05BL TeSys Ultra Control Unit, 0.55 kW, 24 V D","metaDescription":"Schneider TeSys Ultra LUCC05BL advanced control unit for single-phase motor protection, 0.55 kW at 400-440 V AC, 24 V DC control, manual reset, current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.4 in (60 mm)","Range":"TeSys","Reset":"Manual reset","Width":"1.8 in (45 mm)","Height":"2.6 in (66 mm)","Category":"US10I1122397","Load type":"Single-phase motor","Standards":"EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier","Fixing mode":"Plug-in (front face)","Product name":"TeSys Ultra","Motor power kW":"0.55 kW 400...440 V AC 50/60 Hz 1 phase","Operating time":"35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB12 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit","Fire resistance":"1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12","lifecycle_stage":"current","Heat dissipation":"2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38","Range of Product":"TeSys Ultra","Shock resistance":"10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27","Device short name":"LUCC","Network frequency":"40...60 Hz","Compatibility code":"LUCC","Device Application":"Motor control Motor protection","Operating altitude":"6561.68 ft (2000 m)","Tripping threshold":"14.2 x Ir +/- 20 %","Protective treatment":"TH IEC 60068","Utilisation category":"AC-43 AC-41 AC-44","Vibration resistance":"2 gn 5...300 Hz power poles open IEC 60068-2-6 4 gn 5...300 Hz power poles closed IEC 60068-2-6","Nbr. of units in pkg.":"1","Thermal overload class":"Class 10 40...60 Hz -13...131 °F (-25...55 °C) IEC 60947-6-2 Class 10 40...60 Hz -13...131 °F (-25...55 °C) UL 508","IP degree of protection":"IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1","Immunity to microbreaks":"3 ms","Main Function Available":"Protection against phase failure and phase imbalance Protection against overload and short-circuit Manual reset Earth fault protection","Immunity to voltage dips":"70 % / 500 ms IEC 61000-4-11","Product or Component Type":"Advanced control unit","Safe separation of circuit":"400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1","Typical current consumption":"130 mA 24 V DC I maximum while closing with LUB12 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 60 mA 24 V DC I rms sealed with LUB12 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38","Product Specific Application":"Basic protection and advanced functions, communication","[Uc] control circuit voltage":"24 V DC","Resistance to fast transients":"2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4","Resistance to radiated fields":"9.1 V/m (10 V/m) 3 IEC 61000-4-3","[Ui] rated insulation voltage":"690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1","Control circuit voltage limits":"20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out","[Ue] rated operational voltage":"690 V AC","Immunity to radioelectric fields":"10 V IEC 61000-4-6","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Rated Motor Current Adjustment Range":"1.25...5 A","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","Resistance to electrostatic discharge":"8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-6-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$63.50","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d2dc8e97c51d071b3731ced37539e627.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCC05BL/alternatives.json"},"ai":{"faq":[{"question":"What is LUCC05BL's listed depth?","answer":"The depth is 2.4 in (60 mm)."},{"question":"What compliance standards does LUCC05BL meet?","answer":"It complies with IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No 60947-4-1 with phase barrier."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCC05BL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCC05BL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}