{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCCX6ES","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCCX6ES","canonicalUrl":"https://aoctrl.com/schneider/LUCCX6ES","factsUrl":"https://aoctrl.com/api/mcp/products/LUCCX6ES","rawCanonicalId":null},"summary":{"shortDescription":"Advanced control unit, TeSys U, 0.15-0.6A, 1P motors, protection & diagnostic, class 10, coil 48-72V AC/DC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"2.4 in (60 mm)","Range":"TeSys","Reset":"Manual reset","Width":"1.8 in (45 mm)","Height":"2.6 in (66 mm)","Category":"22397-TESYS U - CNTRL MOD(LUCA,LUCD)","Load type":"Single-phase motor","Standards":"EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier","Fixing mode":"Plug-in (front face)","Product name":"TeSys U","Operating time":"35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 60 ms closing with LUB12 control circuit 60 ms closing with LUB32 control circuit 60 ms closing with LUB38 control circuit","Fire resistance":"1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12","lifecycle_stage":"current","Heat dissipation":"2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38","Range of Product":"TeSys U","Shock resistance":"10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27","Device short name":"LUCC","Network frequency":"40...60 Hz","Compatibility code":"LUCC","Device Application":"Motor control Motor protection","Operating altitude":"6561.68 ft (2000 m)","Tripping threshold":"14.2 x Ir +/- 20 %","Protective treatment":"TH IEC 60068","Utilisation category":"AC-44 AC-41 AC-43","Vibration resistance":"2 gn 5...300 Hz power poles open IEC 60068-2-6 4 gn 5...300 Hz power poles closed IEC 60068-2-6","Thermal overload class":"Class 10 40...60 Hz -13...131 °F (-25...55 °C) IEC 60947-6-2 Class 10 40...60 Hz -13...131 °F (-25...55 °C) UL 508","IP degree of protection":"IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1","Immunity to microbreaks":"3 ms","Main Function Available":"Protection against overload and short-circuit Manual reset Protection against phase failure and phase imbalance Earth fault protection","Immunity to voltage dips":"70 % / 500 ms IEC 61000-4-11","Product or Component Type":"Advanced control unit","Non-dissipating shock wave":"1 kV serial mode IEC 60947-6-2 2 kV common mode IEC 60947-6-2","Safe separation of circuit":"400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1","Typical current consumption":"280 mA 48 V AC I maximum while closing with LUB12 280 mA 48 V AC I maximum while closing with LUB32 280 mA 48 V AC I maximum while closing with LUB38 280 mA 48...72 V DC I maximum while closing with LUB12 280 mA 48...72 V DC I maximum while closing with LUB32 280 mA 48...72 V DC I maximum while closing with LUB38 35 mA 48 V AC I rms sealed with LUB12 45 mA 48 V AC I rms sealed with LUB32 45 mA 48 V AC I rms sealed with LUB38 35 mA 48...72 V DC I rms sealed with LUB12 45 mA 48...72 V DC I rms sealed with LUB32 45 mA 48...72 V DC I rms sealed with LUB38","Product Specific Application":"Basic protection and advanced functions, communication","[Uc] control circuit voltage":"48 V AC 48...72 V DC","Resistance to fast transients":"2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4","Resistance to radiated fields":"9.1 V/m (10 V/m) 3 IEC 61000-4-3","[Ui] rated insulation voltage":"690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1","Control circuit voltage limits":"38.5...72 V AC 48 V in operation 38.5...93 V DC 48...72 V in operation 29 V AC 48 V drop-out 29 V DC 48...72 V drop-out","[Ue] rated operational voltage":"690 V AC","Immunity to radioelectric fields":"10 V IEC 61000-4-6","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Rated Motor Current Adjustment Range":"0.15...0.6 A","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","Resistance to electrostatic discharge":"8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-6-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dd9528258a5dd1bf8ec06e08631a3146.pdf","sourceUrl":"https://www.se.com/ph/en/product/LUCCX6ES/advanced-control-unit-tesys-u-0-150-6a-1p-motors-protection-diagnostic-class-10-coil-4872v-ac-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCCX6ES/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCCX6ES","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCCX6ES when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}