{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LUCL18B","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LUCL18B","canonicalUrl":"https://aoctrl.com/schneider/LUCL18B","factsUrl":"https://aoctrl.com/api/mcp/products/LUCL18B","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Ultra LUCL18B magnetic control unit, 3-phase motor protection, 7.5 kW at 400 V AC, 690 V insulation voltage, IP20 front panel, plug-in front face.","salesMarkdown":"It mounts via plug-in front face, sized at 45 mm wide by 66 mm high by 60 mm deep, fitting standard panel layouts. Rated operational voltage is 690 V AC with insulation voltage at 690 V conforming to IEC 60947-6-2 and 600 V per UL 60947-4-1. The unit carries motor power ratings of 7.5 kW at 400...440 V AC, 9 kW at 500 V AC, and 15 kW at 690 V AC, all at 50/60 Hz. Control circuit voltage is 24 V AC, drawing 220 mA during closing and 90 mA sealed. The utilisation categories AC-41, AC-43, and AC-44 define the switching duty. AC-41 covers resistive loads, AC-43 covers motor starting and switching, and AC-44 covers motor switching with inrush currents. The tripping threshold is set at 14.2 x Ir ±20%, meaning the unit trips at 14.2 times the set current rating, providing short-circuit protection for motor circuits. Operating time is 35 ms opening and 70 ms closing with LUB32 or LUB38 control circuit modules. The 3 ms immunity to microbreaks means the unit tolerates brief power interruptions without nuisance tripping, critical for motor control reliability. Voltage dip immunity at 70% for 500 ms per IEC 61000-4-11 ensures ride-through during sags. IP20 protection on the front panel and wired terminals per IEC 60947-1, with IP40 on the front panel outside the connection zone. The plug-in front face fixing means the unit clips into a base or mounting plate without tools, simplifying replacement. Heat dissipation is 3 W for the control circuit with either LUB32 or LUB38 modules. Operating altitude is 2000 m; derate above that. The self-cooled design requires no external ventilation for the motor load path. The LUCL18B complies with EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1 (with phase barrier), and CSA C22.2 No 60947-4-1 (with phase barrier). Safe separation of circuits is rated at 400 V SELV between control and auxiliary circuits, and between control/auxiliary and main circuits per IEC 60947-1. Fire resistance is 960 °C for parts supporting live components per IEC 60695-2-12, and 650 °C for other parts. Protective treatment is TH conforming to IEC 60068 for tropical environments. Shock resistance: 10 gn with power poles open, 15 gn with poles closed per IEC 60068-2-27. Vibration resistance: 2 gn at 5...300 Hz with poles open, 4 gn with poles closed per IEC 60068-2-6.","metaTitle":"Schneider Electric LUCL18B TeSys Ultra Magnetic Control Unit","metaDescription":"Schneider Electric LUCL18B TeSys Ultra magnetic control unit for 3-phase motor protection. Rated 7.5 kW at 400 V AC, 690 V insulation voltage. Current lifecycle stage. Sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"45 mm","Height":"66 mm","Voltage":"690 V AC","Application":"Motor control Motor protection","Fixing Mode":"Plug-in (front face)","Coil Voltage":"24 V AC","Product Status":"Active","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Utilization Category":"AC-41 AC-43 AC-44","Main Product Or Component Type":"Magnetic control unit","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7dee3615281622066658211df93677f6.pdf","sourceUrl":"https://www.se.com/vn/en/product/LUCL18B/standard-control-unit-tesys-ultra-3p-4-5-to-18a-690vac-magnetic-protection-24vac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LUCL18B/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LUCL18B","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LUCL18B when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}