{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV426772","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV426772","canonicalUrl":"https://aoctrl.com/schneider/LV426772","factsUrl":"https://aoctrl.com/api/mcp/products/LV426772","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Compact NSXm Micrologic Vigi 4.1 100A 3P 36kA - lug/busbar","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPact","Colour":"Grey (RAL 7016)","Depth (D)":"80 mm","Standards":"EN/IEC 60947","Width (W)":"108 mm","Height (H)":"144 mm","9 Mm Pitches":"9 module","Control type":"Toggle","Network type":"AC","Product name":"ComPact NSXm","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 4.1","Number of poles":"3P","Protection type":"L : for overload protection (thermal) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection R : for earth-leakage protection","lifecycle_stage":"mature","Connection pitch":"35 mm with spreaders 27 mm without spreaders","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Plate DIN rail","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"ComPact NSXm","Trip unit rating":"100 A at 40 °C","Device short name":"NSXm 100F","Network frequency":"50/60 Hz","Performance level":"F 36 kA 415 V AC","Relative humidity":"0...95 %","Device application":"Protection Distribution","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"100 A at 40 °C","Connection terminals":"compression lug/busbar","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"10000 cycles at 440 V In 20000 cycles at 440 V In/2","Mechanical durability":"20000 cycles","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1000 mA for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1000 mA for class AC 3000 mA for class AC 5000 mA for class AC","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection settings":"No protection 1 x Ir 0.5 x Ir","Protected poles description":"3D","Circuit breaker mounting mode":"By screws Clip-on","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Trip unit protection functions":"LSoIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"5 s at 7.2 x Ir 8 s at 6 x Ir 200 s at 1.5 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"40...100 A","[tsd] Short-time protection delay adjustment range":"0.02 s","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[Δt] Earth-leakage protection time delay adjustment range":"0 ms 60 ms 150 ms 500 ms 1000 ms","[IΔn] earth-leakage protection sensitivity adjustment range":"0.03...5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/98cab0b62fec8d3ff8f7eb56a52b3a6b.pdf","sourceUrl":"https://www.se.com/sg/en/product/LV426772/circuit-breaker-compact-nsxm-micrologic-vigi-4-1-100a-3p-36ka-lug-busbar/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV426772/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV426772","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV426772 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}