{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV429085","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV429085","canonicalUrl":"https://aoctrl.com/schneider/LV429085","factsUrl":"https://aoctrl.com/api/mcp/products/LV429085","rawCanonicalId":null},"summary":{"shortDescription":"LV429085 - UNIT FO by TELEMECANIQUE","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Standards":"EN/IEC 60947-2 UL 508","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.2 G","Number of poles":"4P","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"mature","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Neutral position":"Left","Range of Product":"ComPact NSX100...250","Network Frequency":"50/60 Hz","Device Application":"Generator","Trip unit technology":"Electronic","Nbr. of units in pkg.":"1","Trip unit rated current":"100 A 104 °F (40 °C)","Earth-leakage protection":"Without","Product or Component Type":"Trip unit","Neutral protection settings":"0.5 x Ir 3t + N/2) 1 x Ir 4t) No protection 3t)","Protected poles description":"3t + N/2 4t 3t","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"15 s 1.5 x Ir 0.35 s 7.2 x Ir 0.5 s 6 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"40...100 A","[tsd] Short-time protection delay adjustment range":"0.14 s","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"1.5...9 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$272.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a7f6e0cf515a808d4d273985fc477187.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LV429085/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV429085","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV429085 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}