{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV430408","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV430408","canonicalUrl":"https://aoctrl.com/schneider/LV430408","factsUrl":"https://aoctrl.com/api/mcp/products/LV430408","rawCanonicalId":null},"summary":{"shortDescription":"LV430408 - CIRCUIT BREAKER by SQUARE D","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"3.4 in (86 mm)","Standards":"EN/IEC 60947-2 UL 508","Width (W)":"5.5 in (140 mm)","Height (H)":"6.3 in (161 mm)","Control Type":"Toggle","Network type":"AC","Mounting Mode":"Fixed","Number of poles":"4P","Protection Type":"Without protection","lifecycle_stage":"mature","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Backplate","Neutral position":"Left","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX100...250","Device short name":"NSX160F","Network Frequency":"50/60 Hz","Performance level":"F 36 kA 415 V AC","Upside connection":"Front","Device Application":"Distribution","Line Rated Current":"160 A 104 °F (40 °C)","Downside connection":"Front","Circuit breaker name":"Compact NSX160F","Utilisation category":"Category A","Electrical durability":"40000 cycles 440 V AC 50/60 Hz In/2 IEC 60947-2 15000 cycles 690 V AC 50/60 Hz In/2 IEC 60947-2 20000 cycles 440 V AC 50/60 Hz In IEC 60947-2 7500 cycles 690 V AC 50/60 Hz In IEC 60947-2","Mechanical durability":"40000 cycles IEC 60947-2","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Product or Component Type":"Basic frame","Suitability for isolation":"Yes EN/IEC 60947-2","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kVIEC 60947-2","[Ics] rated service short-circuit breaking capacity":"35 kA 440 V AC 50/60 Hz IEC 60947-2 36 kA 380/415 V AC 50/60 Hz IEC 60947-2 85 kA 220/240 V AC 50/60 Hz IEC 60947-2 22 kA 525 V AC 50/60 Hz IEC 60947-2 30 kA 500 V AC 50/60 Hz IEC 60947-2 8 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"10 kA 600 V AC 50/60 Hz UL 508 85 kA 240 V AC 50/60 Hz UL 508 22 kA Icu 525 V AC 50/60 Hz IEC 60947-2 35 kA Icu 440 V AC 50/60 Hz IEC 60947-2 36 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 85 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 480 V AC 50/60 Hz UL 508 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$480.06","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3f7539fa29a5b0cdb19d143d59d1565e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LV430408/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV430408","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV430408 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}