{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV431400","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV431400","canonicalUrl":"https://aoctrl.com/schneider/LV431400","factsUrl":"https://aoctrl.com/api/mcp/products/LV431400","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker basic frame, ComPact NSX250F, 36kA at 415VAC 50/60 Hz, 250A, without trip unit, 2 poles","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2 UL 508","Width (W)":"105 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Number of poles":"2P","Protection type":"Without protection","lifecycle_stage":"mature","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"ComPact NSX100...250","Device short name":"NSX250F","Network frequency":"50/60 Hz","Performance level":"F 36 kA 415 V AC","Upside connection":"Front","Device application":"Distribution","[In] rated current":"250 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Compact NSX250F","Utilisation category":"Category A","Electrical durability":"10000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 10000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 20000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2 5000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2","Mechanical durability":"20000 cycles conforming to IEC 60947-2","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Product or component type":"Basic frame","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/74417afa570b7bce21a2f0e81b0ed7b2.pdf","sourceUrl":"https://www.se.com/be/en/product/LV431400/circuit-breaker-basic-frame-compact-nsx250f-36ka-at-415vac-50-60-hz-250a-without-trip-unit-2-poles/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV431400/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV431400","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV431400 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}