{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV432082","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV432082","canonicalUrl":"https://aoctrl.com/schneider/LV432082","factsUrl":"https://aoctrl.com/api/mcp/products/LV432082","rawCanonicalId":null},"summary":{"shortDescription":"3P3T MICROLOGIC 2.3 250A TRIP UNIT FOR|3P3T MICROLOGIC 2.3 250A TRIP UNIT FOR","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Standards":"UL 508 EN/IEC 60947-2","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.3","Number of poles":"3P","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"mature","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Range of Product":"ComPact NSX400...630","Network Frequency":"50/60 Hz","Device Application":"Distribution","Trip unit technology":"Electronic","Nbr. of units in pkg.":"1","Trip unit rated current":"250 A 104 °F (40 °C)","Earth-leakage protection":"Without","Product or Component Type":"Trip unit","Protected poles description":"3t","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"11 s 7.2 x Ir 16 s 6 x Ir 400 s 1.5 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"70...250 A","[tsd] Short-time protection delay adjustment range":"0.02 s","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"3000 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e02008b228fe0f1d13420666e6c9f0a0.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LV432082/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV432082","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV432082 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}