{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV432404","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV432404","canonicalUrl":"https://aoctrl.com/schneider/LV432404","factsUrl":"https://aoctrl.com/api/mcp/products/LV432404","rawCanonicalId":null},"summary":{"shortDescription":"3P NSX400H WITHOUT TRIP UNIT COMPACT CT|3P NSX400H WITHOUT TRIP UNIT COMPACT CT","salesMarkdown":null,"metaTitle":"Schneider LV432404 NSX400H Breaker Body","metaDescription":"Schneider LV432404 Compact NSX400H 3-pole molded case breaker body, supplied without trip unit, for power distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"4.3 in (110 mm)","Standards":"EN/IEC 60947-2 UL 508","Width (W)":"5.5 in (140 mm)","Height (H)":"10.04 in (255 mm)","Control Type":"Toggle","Network type":"AC","Mounting Mode":"Fixed","Number of poles":"3P","Protection Type":"Without protection","lifecycle_stage":"mature","Connection pitch":"1.8 in (45 mm)","Mounting Support":"Backplate","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX400...630","Device short name":"NSX400H","Network Frequency":"50/60 Hz","Performance level":"H 70 kA 415 V AC","Upside connection":"Front","Device Application":"Distribution","Line Rated Current":"400 A 104 °F (40 °C)","Downside connection":"Front","Circuit breaker name":"Compact NSX400H","Utilisation category":"Category A","Electrical durability":"12000 cycles 440 V AC 50/60 Hz In/2 IEC 60947-2 3000 cycles 690 V AC 50/60 Hz In IEC 60947-2 6000 cycles 440 V AC 50/60 Hz In IEC 60947-2 6000 cycles 690 V AC 50/60 Hz In/2 IEC 60947-2","Mechanical durability":"15000 cycles IEC 60947-2","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Product or Component Type":"Basic frame","Suitability for isolation":"Yes EN/IEC 60947-2","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kVIEC 60947-2","[Ics] rated service short-circuit breaking capacity":"11 kA 525 V AC 50/60 Hz IEC 60947-2 10 kA 660/690 V AC 50/60 Hz IEC 60947-2 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 50 kA 500 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2 70 kA 380/415 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"85 kA 240 V AC 50/60 Hz UL 508 65 kA 480 V AC 50/60 Hz UL 508 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 35 kA Icu 525 V AC 50/60 Hz IEC 60947-2 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 20 kA 600 V AC 50/60 Hz UL 508"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$760.73 – $885.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7cb93840024b8707f00f5210bb7ca6e1.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LV432404/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV432404","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV432404 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}