{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV432816","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV432816","canonicalUrl":"https://aoctrl.com/schneider/LV432816","factsUrl":"https://aoctrl.com/api/mcp/products/LV432816","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPact NSX630S LV432816 molded case circuit breaker, 4 poles, 630 A switching current, 100 kA breaking capacity Icu at 415 V AC, fixed mount, toggle control, front connection, IP40, IEC/UL certified.","salesMarkdown":"## Overview The LV432816 is a Schneider ComPact NSX630S basic frame molded case circuit breaker rated 630 A continuous with a 100 kA breaking capacity at 415 V AC, built for distribution duty on a 690 V AC supply. Four poles with the neutral on the left, fixed mounting, toggle control, and front connection surfaces top and bottom. Sealed to IP40 with IK07 impact protection. The LV432816 carries 4 poles and 100 kA Icu; the LV432813 is a 3-pole sibling with 85 kA Icu at the same 630 A frame.","metaTitle":"Schneider LV432816 ComPact NSX630S 4-pole 630 A 100 kA MCCB","metaDescription":"Schneider LV432816 ComPact NSX630S MCCB: 4 poles, 630 A rated current, 100 kA breaking capacity at 415 V AC, IEC/UL, fixed mount, toggle control.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"4.3 in (110 mm)","Standards":"EN/IEC 60947-2 UL 508","Width (W)":"7.3 in (185 mm)","Height (H)":"10.04 in (255 mm)","Control Type":"Toggle","Network type":"AC","Mounting Mode":"Fixed","Number of poles":"4P","Protection Type":"Without protection","lifecycle_stage":"mature","Connection pitch":"1.8 in (45 mm)","Mounting Support":"Backplate","Neutral position":"Left","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX400...630","Device short name":"Compact NSX630S","Network Frequency":"50/60 Hz","Performance level":"S 100 kA 415 V AC","Upside connection":"Front","Device Application":"Distribution","Line Rated Current":"630 A 104 °F (40 °C)","Downside connection":"Front","Circuit breaker name":"Compact NSX630S","Utilisation category":"Category A","Electrical durability":"6000 cycles 690 V AC 50/60 Hz In/2 IEC 60947-2 2000 cycles 690 V AC 50/60 Hz In IEC 60947-2 4000 cycles 440 V AC 50/60 Hz In IEC 60947-2 8000 cycles 440 V AC 50/60 Hz In/2 IEC 60947-2","Mechanical durability":"15000 cycles IEC 60947-2","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Product or Component Type":"Basic frame","Suitability for isolation":"Yes EN/IEC 60947-2","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kVIEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 kA 380/415 V AC 50/60 Hz IEC 60947-2 120 kA 220/240 V AC 50/60 Hz IEC 60947-2 65 kA 500 V AC 50/60 Hz IEC 60947-2 90 kA 440 V AC 50/60 Hz IEC 60947-2 12 kA 525 V AC 50/60 Hz IEC 60947-2 12 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"100 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 120 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 40 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA Icu 500 V AC 50/60 Hz IEC 60947-2 90 kA Icu 440 V AC 50/60 Hz IEC 60947-2 25 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,124.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/49ec44404578a7c28a55ad407199dc53.pdf","sourceUrl":"https://www.se.com/ng/en/product/LV432816/circuit-breaker-basic-frame-compact-nsx630s-100ka-at-415vac-50-60-hz-630a-without-trip-unit-4-poles/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV432816/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV432816","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV432816 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}