{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV433307","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV433307","canonicalUrl":"https://aoctrl.com/schneider/LV433307","factsUrl":"https://aoctrl.com/api/mcp/products/LV433307","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Compact NSX100HB1 - Micrologic 5.2 E - 40 A - 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"3.4 in (86 mm)","Standards":"EN/IEC 60947","Width (W)":"4.1 in (105 mm)","Height (H)":"6.3 in (161 mm)","Control Type":"Toggle","Display Type":"LCD display","Network type":"AC","Product name":"ComPact NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 5.2 E","Number of poles":"3P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection","lifecycle_stage":"mature","Connection pitch":"1.4 in (35 mm)","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting Support":"Backplate","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX100...250","Trip unit rating":"40 A 104 °F (40 °C)","Device short name":"NSX100HB1","Network Frequency":"50/60 Hz","Performance level":"HB1 75 kA 690 V AC","Relative humidity":"0...95 %","Upside connection":"Front","Device Application":"Distribution","Line Rated Current":"40 A 104 °F (40 °C)","Operating altitude":"0...6561.68 ft (0...2000 m) without derating 2000 m...5000 m with derating","Downside connection":"Front","Type of Measurement":"Energy meter","Overvoltage category":"Class II","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Demand current and power Energy metering Maximeters/minimeters Maintenance indicators Instantaneous and demand values Power quality Time-stamped histories and event tables Protection and alarm settings","Electrical durability":"10000 cycles 690 V In 20000 cycles 690 V In/2 30000 cycles 440 V In 50000 cycles 440 V In/2","Mechanical durability":"50000 cycles","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Protected poles description":"3t","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"5","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"15...400 s 1.5 x Ir 0.35...11 s 7.2 x Ir 0.5...16 s 6 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"18...40 A","[tsd] Short-time protection delay adjustment range":"0...0.4 s","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Ics] rated service short-circuit breaking capacity":"85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1.5...15 x In","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/899c46eb5d0c4e8f9665800900c96931.pdf","sourceUrl":"https://www.se.com/hk/en/product/LV433307/circuit-breaker-compact-nsx100hb1-micrologic-5-2-e-40-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV433307/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV433307","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV433307 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}