{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV433346","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV433346","canonicalUrl":"https://aoctrl.com/schneider/LV433346","factsUrl":"https://aoctrl.com/api/mcp/products/LV433346","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker, ComPact NSX100HB2, 100kA/690VAC, MicroLogic 6.2E-M trip unit 50A, 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"3.4 in (86 mm)","Standards":"EN/IEC 60947","Width (W)":"4.1 in (105 mm)","Height (H)":"6.3 in (161 mm)","Control Type":"Toggle","Display Type":"LCD display","Network type":"AC","Product name":"ComPact NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Number of poles":"3P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"mature","Connection pitch":"1.4 in (35 mm)","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Mounting Support":"Backplate","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX100...250","Trip unit rating":"50 A 149 °F (65 °C)","Device short name":"NSX100HB2","Network Frequency":"50/60 Hz","Performance level":"HB2 100 kA 690 V AC","Relative humidity":"0...95 %","Upside connection":"Front","Device Application":"Motor","Line Rated Current":"50 A 149 °F (65 °C)","Operating altitude":"0...6561.68 ft (0...2000 m) without derating 2000 m...5000 m with derating","Downside connection":"Front","Type of Measurement":"Energy meter","Motor tripping class":"5 10 20 30","Overvoltage category":"Class II","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Thermal image function Demand current and power Protection and alarm settings Instantaneous and demand values Power quality Energy metering Phase sequence Time-stamped histories and event tables Maximeters/minimeters Maintenance indicators","Electrical durability":"10000 cycles 690 V In 20000 cycles 690 V In/2 30000 cycles 440 V In 50000 cycles 440 V In/2","Mechanical durability":"50000 cycles","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Protected poles description":"3t","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Complementary motor protection":"Underload Stalled rotor Phase unbalance Protracted starting time","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"5","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"10 s 7.2 x Ir 10 120 s 1.5 x Ir 5 20 s 7.2 x Ir 20 240 s 1.5 x Ir 10 26 s 6 x Ir 20 480 s 1.5 x Ir 20 5 s 7.2 x Ir 5 13.5 s 6 x Ir 10 6.5 s 6 x Ir 5 30 s 7.2 x Ir 30 38 s 6 x Ir 30 720 s 1.5 x Ir 30","Short-time protection pick-up adjustment type Isd":"Adjustable","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"25...50 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"100 kA 500 V AC 50/60 Hz IEC 60947-2 100 kA 525 V AC 50/60 Hz IEC 60947-2 100 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.6...1 x In In = 25 A 0.3...1 x In In = 50 A 0.2...1 x In In > 50 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"750 A","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6358b769ae1c46ebdbe4ba297370005a.pdf","sourceUrl":"https://www.se.com/eg/en/product/LV433346/circuit-breaker-compact-nsx100hb2-100ka-690vac-micrologic-6-2em-trip-unit-50a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV433346/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV433346","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV433346 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}