{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV433609","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV433609","canonicalUrl":"https://aoctrl.com/schneider/LV433609","factsUrl":"https://aoctrl.com/api/mcp/products/LV433609","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker, ComPact NSX400R, 200kA/415VAC, MicroLogic 6.3E trip unit 400A, 4 poles 4d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"4.3 in (110 mm)","Standards":"EN/IEC 60947","Width (W)":"7.3 in (185 mm)","Height (H)":"10.04 in (255 mm)","Control Type":"Toggle","Display Type":"LCD display","Network type":"AC","Product name":"ComPact NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.3 E","Number of poles":"4P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"mature","Connection pitch":"1.8 in (45 mm)","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting Support":"Backplate","Neutral position":"Left","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX400...630","Trip unit rating":"400 A 104 °F (40 °C)","Device short name":"NSX400R","Network Frequency":"50/60 Hz","Performance level":"R 200 kA 415 V AC","Relative humidity":"0...95 %","Upside connection":"Front","Device Application":"Distribution","Line Rated Current":"400 A 104 °F (40 °C)","Operating altitude":"0...6561.68 ft (0...2000 m) without derating 2000 m...5000 m with derating","Downside connection":"Front","Type of Measurement":"Energy meter","Overvoltage category":"Class II","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Protection and alarm settings Instantaneous and demand values Energy metering Demand current and power Maximeters/minimeters Power quality Time-stamped histories and event tables Maintenance indicators","Electrical durability":"3000 cycles 690 V In 6000 cycles 690 V In/2 6000 cycles 440 V In 12000 cycles 440 V In/2","Mechanical durability":"15000 cycles","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Neutral protection settings":"0.5 x Ir 3t + N/2) 1 x Ir 4t) 1.6 x Ir 3t + OSN) No protection 3t)","Protected poles description":"3t 3t + OSN 3t + N/2 4t","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"6","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable 5 settings","[Tr] Long-Time Protection Delay Adjustment Range":"15...400 s 1.5 x Ir 0.35...11 s 7.2 x Ir 0.5...16 s 6 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"160...400 A","[tsd] Short-time protection delay adjustment range":"0...0.4 s","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Ics] rated service short-circuit breaking capacity":"200 kA 220/240 V AC 50/60 Hz IEC 60947-2 200 kA 380/415 V AC 50/60 Hz IEC 60947-2 200 kA 440 V AC 50/60 Hz IEC 60947-2 80 kA 500 V AC 50/60 Hz IEC 60947-2 65 kA 525 V AC 50/60 Hz IEC 60947-2 45 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"200 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 200 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 200 kA Icu 440 V AC 50/60 Hz IEC 60947-2 80 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 525 V AC 50/60 Hz IEC 60947-2 45 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"1.5...12 x In","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"1.5...12 x In","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7fb951b7beb0f9a842766ade240c5afe.pdf","sourceUrl":"https://www.se.com/th/en/product/LV433609/circuit-breaker-compact-nsx400r-200ka-415vac-micrologic-6-3e-trip-unit-400a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV433609/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV433609","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV433609 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}