{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV433723","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV433723","canonicalUrl":"https://aoctrl.com/schneider/LV433723","factsUrl":"https://aoctrl.com/api/mcp/products/LV433723","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker ComPact NSX630HB1, 75 kA at 690 VAC, MicroLogic 2.3 M trip unit 500 A, 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"ComPact","Category":"US10DE201101","Depth (D)":"4.3 in (110 mm)","Standards":"EN/IEC 60947","Width (W)":"5.5 in (140 mm)","Height (H)":"10.04 in (255 mm)","Control Type":"Toggle","Network type":"AC","Product name":"ComPact NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.3 M","Number of poles":"3P","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"mature","Connection pitch":"1.8 in (45 mm)","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Mounting Support":"Backplate","Pollution degree":"3 IEC 60664-1","Range of Product":"ComPact NSX400...630","Trip unit rating":"500 A 149 °F (65 °C)","Device short name":"NSX630HB1","Network Frequency":"50/60 Hz","Performance level":"HB1 75 kA 690 V AC","Relative humidity":"0...95 %","Upside connection":"Front","Device Application":"Motor","Line Rated Current":"500 A 149 °F (65 °C)","Operating altitude":"0...6561.68 ft (0...2000 m) without derating 2000 m...5000 m with derating","Downside connection":"Front","Motor tripping class":"20 10 5","Overvoltage category":"Class II","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"2000 cycles 690 V In 6000 cycles 690 V In/2 4000 cycles 440 V In 8000 cycles 440 V In/2","Mechanical durability":"15000 cycles","Nbr. of units in pkg.":"1","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Protected poles description":"3t","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Complementary motor protection":"Phase unbalance","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"6","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"10 s 7.2 x Ir 10 120 s 1.5 x Ir 5 20 s 7.2 x Ir 20 240 s 1.5 x Ir 10 26 s 6 x Ir 20 480 s 1.5 x Ir 20 5 s 7.2 x Ir 5 13.5 s 6 x Ir 10 6.5 s 6 x Ir 5","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"250...500 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","[Ii] instantaneous protection pick-up adjustment range":"6500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3074441ede2e5a45cb5aed4e31a8cd5.pdf","sourceUrl":"https://www.se.com/uk/en/product/LV433723/circuit-breaker-compact-nsx630hb1-75-ka-at-690-vac-micrologic-2-3-m-trip-unit-500-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV433723/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV433723","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV433723 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}