{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV436066","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV436066","canonicalUrl":"https://aoctrl.com/schneider/LV436066","factsUrl":"https://aoctrl.com/api/mcp/products/LV436066","rawCanonicalId":null},"summary":{"shortDescription":"trip unit - Micrologic 6.3 E-M 400 A - 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPact","Standards":"EN/IEC 60947-2 UL 508","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.3 E-M","Number of poles":"3P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"mature","Pollution degree":"3 conforming to IEC 60529","Range of product":"ComPact NSX400...630","Network frequency":"50/60 Hz","Device application":"Motor","Type of measurement":"Energy meter","Trip unit technology":"Electronic","Communication of data":"Protection and alarm settings Time-stamped histories and event tables Maintenance indicators Power quality Maximeters/minimeters Demand current and power Energy metering Instantaneous and demand values","IP degree of protection":"IP40 conforming to IEC 60529","Trip unit rated current":"400 A at 40 °C","Electrical data recording":"Maintenance indicators","Product or component type":"Control unit","Protected poles description":"3t","Circuit breaker mounting mode":"Fixed","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"15...400 s at 1.5 x Ir 0.35...11 s at 7.2 x Ir 0.5...16 s at 6 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"160...400 A","[tsd] Short-time protection delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1.5...11 x In Compact NSX630 1.5...12 x In Compact NSX400","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6c9ffa218679e3ccda2e5307e4a37516.pdf","sourceUrl":"https://www.se.com/sa/en/product/LV436066/trip-unit-micrologic-6-3-em-400-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV436066/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV436066","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV436066 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}