{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV510426","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV510426","canonicalUrl":"https://aoctrl.com/schneider/LV510426","factsUrl":"https://aoctrl.com/api/mcp/products/LV510426","rawCanonicalId":null},"summary":{"shortDescription":"switch disconnector, EasyPact CVS100NA, 4 poles, 100A, AC22A, AC23A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Range":"EasyPact","Width":"140 mm","Height":"161 mm","Standards":"EN 60947-3 IEC 60947-3","Control type":"Toggle","Network type":"AC","Product name":"EasyPact CVS","Mounting mode":"Fixed","Visible break":"No","lifecycle_stage":"mature","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact CVS100...250","Device short name":"CVS100NA","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","Downside connection":"Front","Utilisation category":"AC-23A AC-22A","Electrical durability":"AC-22A: 8000 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 8000 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3","Mechanical durability":"30000 cycles conforming to IEC 60947-3","Breaking capacity code":"NA","Earth-leakage protection":"Without","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN 60947-3 Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ie] rated operational current":"AC-22A: 100 A AC 50/60 Hz 220/240 V AC-22A: 100 A AC 50/60 Hz 380/415 V AC-22A: 100 A AC 50/60 Hz 440 V AC-23A: 100 A AC 50/60 Hz 220/240 V AC-23A: 100 A AC 50/60 Hz 380/415 V AC-23A: 100 A AC 50/60 Hz 440 V","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Icw] rated short-time withstand current":"0.69 kA during 20 s conforming to IEC 60947-3 1.8 kA during 1 s conforming to IEC 60947-3 1.8 kA during 3 s conforming to IEC 60947-3","[Icm] rated short-circuit making capacity":"75 kA with upstream protection circuit breaker 2.6 kA switch-disconnector alone","[Ith] conventional free air thermal current":"100 A at 50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/676f21d307e133f648017c6aedf00aa1.pdf","sourceUrl":"https://www.se.com/vn/en/product/LV510426/switch-disconnector-easypact-cvs100na-4-poles-100a-ac22a-ac23a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV510426/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV510426","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV510426 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}