{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV510737","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV510737","canonicalUrl":"https://aoctrl.com/schneider/LV510737","factsUrl":"https://aoctrl.com/api/mcp/products/LV510737","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker, EasyPact CVS160B, 25kA at 415VAC, 100A, TM-G trip unit, 3P3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Range":"EasyPact","Width":"105 mm","Height":"161 mm","Standards":"IEC 60947-2","Control type":"Toggle","Network type":"AC","Product name":"EasyPact CVS","Mounting mode":"Fixed","Trip unit name":"TM-G","Protection type":"Overload protection (thermal) Short-circuit protection (magnetic)","lifecycle_stage":"mature","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact CVS100...160","Trip unit rating":"100 A at 40 °C","Device short name":"CVS160B","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Compatibility code":"CVS160","Device application":"Distribution","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"12000 cycles 415 V In conforming to IEC 60947-2","Mechanical durability":"25000 cycles","Breaking capacity code":"B","Connections - terminals":"Screw connection","IP degree of protection":"IP40","[Icu] Breaking capacity":"40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2","Product or component type":"Circuit breaker","Contact position indicator":"Yes","Protected poles description":"3D","Long time delay adjustment type":"Fixed","Electrical shock protection class":"Class II","Long time pick-up adjustment range":"0.7...1 x In","Ambient air temperature for storage":"-50...85 °C","Thermal protection adjustment range":"70...100 A","Long time pick-up adjustment type Ir":"Adjustable","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2","Earth leakage protection (Vigi add on)":"Without","[Uimp] rated impulse withstand voltage":"8 kV conforming to EN/IEC 60947-2","Instantaneous pick-up adjustment type Ii":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d10d6f4f5ecae5daf84e70d10009f53a.pdf","sourceUrl":"https://www.se.com/vn/en/product/LV510737/circuit-breaker-easypact-cvs160b-25ka-at-415vac-100a-tmg-trip-unit-3p3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV510737/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV510737","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV510737 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}