{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV839069","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV839069","canonicalUrl":"https://aoctrl.com/schneider/LV839069","factsUrl":"https://aoctrl.com/api/mcp/products/LV839069","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2, LV839069, 800 A, 3-pole, drawout, breaking capacity, 200 kA Icu at 254 V AC 60 Hz, 16.8 x 17.5 x 17.3 in.","salesMarkdown":"The LV839069 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 800 A at 40 °C. That 800 A line current is the continuous rating in a 104 °F ambient — the number you use for cable and bus sizing, not a peak or short-time figure. The breaking capacity code means it delivers 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, dropping to 130 kA at 635 V AC 60 Hz. For a buyer matching an existing switchboard spec, the drawout cradle and base-plate-rail mounting (connection pitch 4.5 in) are the mechanical fit check — the 17.5 in width and 16.8 in depth tell you whether it lands in the existing cell without a bucket rework. ## What the interrupting ratings mean in practice At 508 V AC 60 Hz the Icu is 200 kA; at 635 V AC 60 Hz it drops to 130 kA. The rated short-time withstand current (Icw) is 30 kA for 0.5 s per ANSI C37.50, which governs selectivity coordination with downstream breakers during a delayed trip. Integral instantaneous protection is set at 49.5 to 55.5 kA, and the maximum breaking time is 9 ms — fast enough to limit let-through energy on a high-fault bus. Mechanical durability is 12,500 cycles; electrical durability 2,800 cycles under ANSI C37.50 — numbers that matter for a breaker that sees regular switching, not just fault backup.","metaTitle":"LV839069 MasterPact MTZ2 800A 3P Drawout, 200kA Icu","metaDescription":"Obsolete LV839069 MasterPact MTZ2 circuit breaker, 800A, 3-pole, drawout, 200 kA Icu at 254 V AC 60 Hz. Sourced to order against RFQ through independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"16.8 in (426.8 mm)","Width":"17.5 in (444.3 mm)","Height":"17.3 in (438.8 mm)","Application":"Protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"4.5 in (115 mm)","Safety Category":"200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50","Electrical Life Cycles":"2800 cycles ANSI C37.50","Mechanical Life Cycles":"12500 cycles ANSI C37.50","Main Product Or Component Type":"Circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5b48a73f9b85da568ae261d1c675298c.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV839069/circuit-breaker-masterpact-mtz2-ansi-max-800a-rated-3-pole-drawout-mount-l1-breaking-cap-635vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV839069/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV839069","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV839069 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}