{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV839081","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV839081","canonicalUrl":"https://aoctrl.com/schneider/LV839081","factsUrl":"https://aoctrl.com/api/mcp/products/LV839081","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ3 ANSI circuit breaker, LV839081, 3-pole drawout, 6000 A rated, breaking capacity, 635 VAC, without Micrologic trip unit.","salesMarkdown":"Drawout mounting on a base plate with rails. The footprint is 17.5 in wide × 17.3 in tall × 16.8 in deep, with a connection pitch of 9.06 in (230 mm). That's a standard ANSI drawout cutout — verify your switchgear cubicle dimensions against the MTZ3 mounting template before committing the panel layout.","metaTitle":"Schneider LV839081 MasterPact MTZ3 6000A 3P Drawout Breaker","metaDescription":"LV839081 MasterPact MTZ3 ANSI circuit breaker, 6000 A rated, 3-pole drawout, 200 kA Icu at 254 VAC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"16.8 in (426.8 mm)","Width":"17.5 in (444.3 mm)","Height":"17.3 in (438.8 mm)","Application":"Protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"9.06 in (230 mm)","Safety Category":"200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50","Electrical Life Cycles":"1000 cycles ANSI C37.50","Mechanical Life Cycles":"10000 cycles ANSI C37.50","Main Product Or Component Type":"Circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f5e82c6dd063900686648dcbaf437a8.pdf","sourceUrl":"https://www.se.com/ca/en/product/LV839081/circuit-breaker-masterpact-mtz3-ansi-max-6000a-rated-3-pole-drawout-mount-l1-breaking-cap-635vac-w-o-micrologic-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV839081/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV839081","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV839081 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}