{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV839094","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV839094","canonicalUrl":"https://aoctrl.com/schneider/LV839094","factsUrl":"https://aoctrl.com/api/mcp/products/LV839094","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Masterpact MTZ3 60 HC, LV839094, switch disconnector, 6000 A, 3P, fixed, ANSI, 200 kA Icu at 254 V AC.","salesMarkdown":"The Schneider Electric Masterpact MTZ3 60 HC (LV839094) is a fixed-mounted, three-pole switch disconnector rated for 6000 A at 104 °F (40 °C) — that is the continuous current it carries without derating in a typical distribution panel. ## Deployment context Fixed mounting means this unit bolts directly into a switchboard or MCC lineup — no draw-out cradle. The 30.2 in (767 mm) width and 13.9 in (352.2 mm) height fit standard ANSI switchgear cubicle openings; the 11.7 in (297.7 mm) depth leaves room for rear cable lugs or bus connections. Push-button control on the front cover gives local open/close without opening the door.","metaTitle":"LV839094 Masterpact MTZ3 60 HC Switch Disconnector, 6000 A,","metaDescription":"Active Masterpact MTZ3 60 HC switch disconnector, 6000 A rated operational current, 200 kA Icu breaking capacity at 254 V AC. Sourced to order against RFQ. LV839094 specifications:","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"11.7 in (297.7 mm)","Width":"30.2 in (767 mm)","title":"LV839094","Height":"13.9 in (352.2 mm)","description":"Automatic, switch disconnector, Masterpact MTZ3, 60 HC, 6000A, ANSI, 3P, fixed","Control Type":"Push-button","Network type":"AC","Mounting Mode":"Fixed","lifecycle_stage":"current","Connection pitch":"9.06 in (230 mm)","Breaking capacity":"200.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 200.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 130.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50","Device short name":"MTZ3 60 HC","Network Frequency":"50/60 Hz","Poles description":"3P","Device Application":"Distribution","Nbr. of units in pkg.":"1","Product or Component Type":"Switch disconnector","[Ie] rated operational current":"6000 A 104 °F (40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/acf99dfad13425494fb103f5b0711dac.pdf","sourceUrl":"https://www.se.com/us/en/product/LV839094/automatic-switch-disconnector-masterpact-mtz3-60-hc-6000a-ansi-3p-fixed/"},"ai":{"faq":[{"question":"Where can I buy LV839094 and get current pricing?","answer":"We source and quote LV839094 to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ through this listing."},{"question":"What are the key ratings for LV839094?","answer":"Rated operational current 6000 A at 104 °F (40 °C); breaking capacity 200 kA Icu at 254 V AC, 200 kA Icu at 508 V AC, and 130 kA Icu at 635 V AC (all with external relay per ANSI C37.50). Three-pole, fixed-mounted, push-button control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV839094","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV839094 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}