{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV839108","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV839108","canonicalUrl":"https://aoctrl.com/schneider/LV839108","factsUrl":"https://aoctrl.com/api/mcp/products/LV839108","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ1, LV839108, UL 489 circuit breaker, 800 A rated, 3 pole, fixed mount, H breaking capacity, 65 kA Icu 240 V AC, 50/60 Hz.","salesMarkdown":"## What this MasterPact MTZ1 delivers The LV839108 is a fixed-mount MasterPact MTZ1 circuit breaker from Schneider Electric, rated 800 A at 40 °C, 3-pole, with H breaking capacity code. It carries UL 489 listing and delivers 65 kA Icu at 240 V AC, 50 kA Icu at 480 V AC, and 50 kA Icu at 600 V AC — the interrupting rating you need to match the available fault current at your service entrance or distribution panel. The 35 kA Icw (0.5 s per UL 489) gives you short-time withstand for selective coordination downstream. Mechanical durability is rated at 10,000 cycles (ANSI C37.50), electrical durability at 1,000 cycles — figures that tell you this breaker is built for main or feeder duty where you cycle it infrequently but need it to clear faults reliably. The integral instant protection range of 81–99 kA means the magnetic trip acts fast on high faults, while the 25–30 ms maximum breaking time keeps arc energy contained. Fixed mounting on base plate rails, with a connection pitch of 70 mm. Dimensions: width 276.2 mm, height 300.5 mm, depth 209 mm. That depth (8.2 in) matters when you're laying out the gland plate or door clearance — it's a standard drawout-equivalent footprint for the MTZ1 frame.","metaTitle":"Schneider LV839108 MasterPact MTZ1 800A 3P Fixed Circuit Bre","metaDescription":"Schneider LV839108 MasterPact MTZ1 circuit breaker, 800 A rated, 3 pole, fixed mount, H breaking capacity, 65 kA Icu at 240 V, UL 489 listed. Active production, sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"8.2 in (209 mm)","Width":"10.9 in (276.2 mm)","Height":"11.8 in (300.5 mm)","Application":"Protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"2.8 in (70 mm)","Safety Category":"65 kA Icu 240 V AC 60 Hz UL 489 50 kA Icu 480 V AC 60 Hz UL 489 50 kA Icu 600 V AC 60 Hz UL 489","Electrical Life Cycles":"1000 cycles ANSI C37.50","Mechanical Life Cycles":"10000 cycles ANSI C37.50","Main Product Or Component Type":"Circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/024dab469752d46685cfe281f1dba031.pdf","sourceUrl":"https://www.se.com/ca/en/product/LV839108/circuit-breaker-masterpact-mtz1-ul-489-max-800a-rated-3-pole-fixed-mount-h-breaking-cap-600vac-w-o-micrologic-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV839108/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV839108","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV839108 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}