{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV839307","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV839307","canonicalUrl":"https://aoctrl.com/schneider/LV839307","factsUrl":"https://aoctrl.com/api/mcp/products/LV839307","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ3, LV839307, 3-pole drawout air circuit breaker, 4000 A rated, H2 breaking capacity (85 kA Icu at 508 VAC), without Micrologic trip unit, with ArcBlok.","salesMarkdown":"## What you're specifying The LV839307 is a MasterPact MTZ3 drawout air circuit breaker — 3-pole, 4000 A continuous rating at 40 °C, with H2 breaking capacity delivering 85 kA Icu at 508 VAC (also 85 kA at 254 VAC and 635 VAC per ANSI C37.50). This is the frame and mechanism only: it ships without a Micrologic trip unit, so you'll need to order the protection relay separately. The ArcBlok arc-extinction chamber is integral. Drawout mounting means this breaker slides into a cradle — no hard wiring for the main power connections during swap-out. Rated short-time withstand (Icw) is 85 kA for 0.5 s, which gives you selectivity headroom downstream. Mechanical durability is 5000 cycles; electrical durability 1000 cycles per ANSI C37.50. ## Breaking capacity — what it means for coordination The H2 code tells you the interrupting rating: 85 kA Icu at 254 V, 508 V, and 635 V AC. That's a flat 85 kA across the full ANSI voltage range, not a derated curve. For a 4000 A main breaker feeding a switchboard, that SCCR covers most industrial service-entrance and distribution applications without cascading upstream. Maximum breaking time is 25 to 30 ms; maximum closing response time is 70 ms. The 85 kA Icw for 0.5 s supports delayed tripping for selective coordination with downstream feeders — you can let a fault ride through on the feeder breaker without pulling the main. The drawout chassis measures 31.07 in wide by 18.8 in high by 16.8 in deep, with a connection pitch of 9.06 in (230 mm) between phase centers. Mounting is on base plate rails — this is a floor-mount switchgear frame, not a DIN-rail clip. Verify your cell opening and bus bar spacing before committing the cutout.","metaTitle":"LV839307 MasterPact MTZ3 4000A 3P Drawout Circuit Breaker","metaDescription":"Schneider LV839307 MasterPact MTZ3, 4000A rated, 3P, drawout, 85kA Icu at 508VAC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"16.8 in (426.8 mm)","Width":"31.07 in (789.1 mm)","Height":"18.8 in (478.1 mm)","Application":"Protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"9.06 in (230 mm)","Safety Category":"85 kA Icu 254 V AC 50/60 Hz ANSI C37.50 85 kA Icu 508 V AC 50/60 Hz ANSI C37.50 85 kA Icu 635 V AC 50/60 Hz ANSI C37.50","Electrical Life Cycles":"1000 cycles ANSI C37.50","Mechanical Life Cycles":"5000 cycles ANSI C37.50","Main Product Or Component Type":"Circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1fe305cabcbe33beb99719abffc3b7b4.pdf","sourceUrl":"https://www.se.com/us/en/product/LV839307/circuit-breaker-masterpact-mtz3-ansi-max-4000a-rated-3-pole-drawout-mount-h2-breaking-cap-635vac-w-o-micrologic-trip-unit-w-arcblok/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV839307/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV839307","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV839307 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}