{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846175","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846175","canonicalUrl":"https://aoctrl.com/schneider/LV846175","factsUrl":"https://aoctrl.com/api/mcp/products/LV846175","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MasterPact MTZ2, drawout circuit breaker, 3P, 2500 A at 40 °C, H2V 100 kA 415 V AC performance, depth 403 mm, width 441 mm, height 439 mm.","salesMarkdown":"The LV846175 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 2500 A continuous at 40 °C. That 2500 A frame is the backbone of a main or tie breaker in a low-voltage switchboard — it carries the full load of a large distribution transformer or a high-density industrial feeder without forced cooling. That is Category B selectivity, so downstream breakers can be coordinated to isolate only the faulted branch while the main stays closed on a through-fault. Short-time withstand (Icw) is 100 kA for 1 second. Impulse withstand (Uimp) is 12 kV; insulation voltage (Ui) is 1000 V. Drawout mounting means the breaker cassette stays wired to the bus; the breaker itself racks out for maintenance or replacement without disturbing the power connections. Mounting support is rails or base plate — standard for switchgear cubicle integration. ## Sourcing and lifecycle — current production, no obsolescence concern Compliance documentation is covered by the standards listed: EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. These are the governing standards for low-voltage switchgear and controlgear assemblies, covering the breaker's design, testing, and isolation suitability. ## Integration — what fits in the cubicle Footprint is 441 mm wide by 439 mm high by 403 mm deep — a standard drawout cassette size for the MTZ2 frame. Connection pitch is 115 mm between phase centers, matching the bus-bar drilling pattern on most low-voltage switchgear lineups. Upside and downside connections are both available in front or rear configurations — the same breaker can be ordered for either cable-entry topology without a hardware change. Power dissipation at rated current is 600 W — account for that heat in the cubicle ventilation budget. Altitude derating starts above 2000 m — no derating needed for most industrial sites. ## Durability and response — what the cycle counts mean for maintenance planning Mechanical durability is 15,000 cycles with periodic preventive maintenance — that is the mechanism life before a major overhaul. Electrical durability is 5000 cycles at rated current at 440 V AC under EN/IEC 60947-2 AC-23A duty, and 6000 cycles under EN/IEC 60947-3 AC-3 motor-switching duty. For a main breaker that operates a few times a year, that is decades of service. Maximum breaking time is 25 ms; maximum closing response time is 70 ms. These are the mechanical operating times — the actual arc-extinction time is shorter and depends on the fault current level.","metaTitle":"Schneider Electric LV846175 MasterPact MTZ2 2500 A Circuit B","metaDescription":"Schneider Electric LV846175 MasterPact MTZ2 drawout circuit breaker, 2500 A rated current, 100 kA Icu at 440 V AC. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"403 mm","Width":"441 mm","Height":"439 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Electrical Life Cycles":"5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Mechanical Life Cycles":"15000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$8,619.21 – $16,108.88","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c28eefb8ab479fbfe1ba8a7f599d2eea.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV846175/circuit-breaker-frame-masterpact-mtz2-25h2v-drawout-for-micrologic-x-2500a-100ka-415vac-icu-icw-3p/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV846175/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846175","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846175 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}