{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846182","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846182","canonicalUrl":"https://aoctrl.com/schneider/LV846182","factsUrl":"https://aoctrl.com/api/mcp/products/LV846182","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ2, LV846182, fixed circuit breaker, 4P, 1250 A at 40 °C, H2V 100 kA 415 V AC.","salesMarkdown":"The LV846182 is a MasterPact MTZ2 fixed circuit breaker from Schneider Electric's MasterPacT range, built for power distribution protection in industrial and commercial switchboards. The 4-pole design with neutral on the left is common for three-phase + N distribution. Selectivity category B means it coordinates with downstream breakers to isolate only the faulted branch — a key requirement for maintaining uptime on a critical bus. ## Breaking capacity and what that means for your panel The H2V performance level delivers 100 kA Ics at 415 V AC and 440 V AC. ## Integration and mounting constraints Fixed mounting on rails or a base plate. The 537 mm width, 352 mm height, and 300 mm depth — plus the 115 mm connection pitch — determine the panel cutout and busbar layout. Front or rear connections on both the line and load sides give flexibility for cable entry direction. IP30 means no protection against water ingress; install inside a switchboard enclosure rated for the environment. Derate above 2000 m altitude. Suitability for isolation per EN/IEC 60947-2 means it provides a visible break and meets the safety requirements for disconnecting a circuit.","metaTitle":"Schneider Electric LV846182 MasterPact MTZ2 1250 A Circuit B","metaDescription":"Schneider Electric LV846182 MasterPact MTZ2 fixed circuit breaker, 1250 A rated current, 100 kA breaking capacity at 440 V AC. Active production. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"537 mm","Height":"352 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Electrical Life Cycles":"10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Mechanical Life Cycles":"15000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,248.80 – $14,447.73","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0e2fad3058a918fd680c0f5cbbc12380.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV846182/circuit-breaker-frame-masterpact-mtz2-12h2v-fixed-for-micrologic-x-1250a-100ka-415vac-icu-icw-4p/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV846182/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846182","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846182 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}