{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846192","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846192","canonicalUrl":"https://aoctrl.com/schneider/LV846192","factsUrl":"https://aoctrl.com/api/mcp/products/LV846192","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ2, LV846192, 4P drawout circuit breaker, 1250 A rated at 40 °C, H2V 100 kA breaking capacity at 415 V AC.","salesMarkdown":"The LV846192 is a MasterPact MTZ2 drawout circuit breaker from the MasterPacT range, rated 1250 A at 40 °C with an H2V performance class giving 100 kA breaking capacity at 415 V AC. It's a 4-pole unit (neutral left) built for power distribution protection in switchgear — Category B selectivity means it coordinates with downstream breakers to isolate faults without blacking out the whole bus. Rated insulation voltage is 1000 V AC, operational voltage 440 V AC, and it carries a 12 kV impulse withstand. The 100 kA rated short-time withstand (Icw) holds for 1 second — enough for most upstream coordination windows — and the making capacity (Icm) hits 220 kA at 440 V. Drawout mounting on rails or a base plate, with front and rear connection options on both the line and load sides. Connection pitch is 115 mm. Dimensions: 556 mm wide, 439 mm high, 403 mm deep — that depth matters for enclosure sizing; the breaker needs a full 403 mm clearance behind the door for the drawout mechanism to rack out. ## Breaking performance and coordination Service breaking capacity (Ics) is 100 kA at both 220/415 V and 440 V AC — that's 100% of the ultimate capacity (Icu), meaning it can reclose and carry load after a fault at that level without derating. Maximum breaking time is 25 ms; closing response time 70 ms. Electrical durability: 10,000 cycles at In under AC-23A (motor switching), 6,000 cycles under AC-3. Mechanical durability is 15,000 cycles with periodic preventive maintenance. Standards compliance covers EN/IEC 60947-1, 60947-2, 60947-2 Annex H (for Category B selectivity), and IEC 61557-12 (for power metering if a trip unit with metering is installed).","metaTitle":"LV846192 MasterPact MTZ2 4P 1250A Drawout Circuit Breaker, 1","metaDescription":"LV846192 MasterPact MTZ2 drawout circuit breaker, 4P, 1250 A at 40 °C, H2V 100 kA at 415 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"403 mm","Width":"556 mm","Height":"439 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Electrical Life Cycles":"10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Mechanical Life Cycles":"15000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,319.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3a956d9287e7eac7dc5877ccc7920457.pdf","sourceUrl":"https://www.se.com/vn/en/product/LV846192/circuit-breaker-frame-masterpact-mtz2-12h2v-drawout-for-micrologic-x-1250a-100ka-415vac-icu-icw-4p/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV846192/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846192","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846192 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}