{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846207","canonicalUrl":"https://aoctrl.com/schneider/LV846207","factsUrl":"https://aoctrl.com/api/mcp/products/LV846207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2, LV846207, 4P fixed circuit breaker, 4000 A at 40 °C, H2V 100 kA at 415 V AC, 537 x 352 x 300 mm.","salesMarkdown":"## What this MasterPact MTZ2 carries The LV846207 is a MasterPact MTZ2 4P fixed circuit breaker rated 4000 A at 40 °C, with an H2V performance class delivering 100 kA breaking capacity at 415 V AC. It is a Category B breaker (selectivity type) per EN/IEC 60947-2, meaning it coordinates with downstream devices to isolate only the faulted branch during a short circuit — critical for maintaining power to healthy loads in a distribution panel. ## Breaking capacity and fault handling Rated service breaking capacity (Ics) is 100 kA at both 220/415 V AC and 440 V AC, so the breaker can clear a fault and be reclosed without replacement. Short-time withstand (Icw) holds 100 kA for 1 second — enough for selective coordination with upstream gear. Making capacity (Icm) reaches 220 kA at 440 V AC, covering the peak asymmetrical current on a bolted fault. Maximum total break time is 25 ms; closing response is 70 ms. Fixed-mount chassis, 537 mm wide x 352 mm high x 300 mm deep. Connection pitch is 115 mm. Both upside and downside connections accept front or rear terminations — choose based on switchboard bus run. Mounting support is rails or base plate; neutral is on the right. IP30 enclosure suits indoor switchgear; pollution degree 3 per IEC 60947-1 means it tolerates conductive dust in industrial environments.","metaTitle":"LV846207 MasterPact MTZ2 4000A Circuit Breaker, 100 kA","metaDescription":"LV846207 MasterPact MTZ2 4P fixed circuit breaker, 4000 A at 40 °C, 100 kA breaking capacity at 440 V AC. Current lifecycle, sourced to order. Standards EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"537 mm","Height":"352 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Electrical Life Cycles":"5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Mechanical Life Cycles":"15000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$20,929.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9373c7aa2e942dc7ade2de3a4ec2065b.pdf","sourceUrl":"https://www.se.com/ph/en/product/LV846207/circuit-breaker-masterpact-mtz2-40-h2v-4000-a-4-poles-fixed-without-trip-unit-right-neutral/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV846207/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}