{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846214","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846214","canonicalUrl":"https://aoctrl.com/schneider/LV846214","factsUrl":"https://aoctrl.com/api/mcp/products/LV846214","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MasterPact MTZ2, 4P drawout circuit breaker, LV846214, rated 2000 A at 40 °C, H2V performance 100 kA at 415 V AC.","salesMarkdown":"## MasterPact MTZ2 20 H2V — 2000 A drawout breaker The LV846214 is a MasterPact MTZ2 4-pole drawout circuit breaker from the MasterPacT range, rated 2000 A at 40 °C with an H2V performance class delivering 100 kA breaking capacity at 415 V AC. It is designed for power distribution protection in industrial and commercial switchboards where Category B selectivity is required — meaning it maintains discrimination with downstream breakers during a fault, so only the affected circuit opens. Rated service breaking capacity (Ics) is 100 kA at both 220/415 V AC and 440 V AC — full rated short-circuit capacity, not a reduced service rating. Short-time withstand (Icw) holds 100 kA for 0.5 s and 1 s, and 75 kA for 3 s, giving the protection engineer headroom for selective coordination with downstream feeders. Making capacity (Icm) reaches 220 kA at 440 V AC, confirming the breaker can close onto a bolted fault without contact welding. Drawout mounting on rails or a base plate, with front and rear connection options on both the upside and downside. Connection pitch is 115 mm. Neutral position is on the right. The breaker is 556 mm wide, 439 mm tall, and 403 mm deep — verify the switchgear cell dimensions against these before specifying. IP30 protection conforming to EN 60529 suits enclosed panel installation; not rated for washdown environments. Altitude rating is 0 to 2000 m without derating, 2000 to 5000 m with derating.","metaTitle":"LV846214 MasterPact MTZ2 4P Drawout Circuit Breaker, 2000 A,","metaDescription":"LV846214 MasterPact MTZ2 4P drawout circuit breaker. Rated 2000 A at 40 °C, 100 kA breaking capacity at 440 V AC. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"403 mm","Range":"MasterPacT","Width":"556 mm","title":"LV846214","Height":"439 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"circuit breaker, Masterpact MTZ2 20 H2V, 2000 A, 4 poles, drawout, without trip unit, right neutral","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting mode":"Drawout","Sensor rating":"1000 A 1250 A 1600 A 2000 A","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H2V 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ2 20 H2V","Poles description":"4P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"2000 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"15000 cycles with periodic preventive maintenance","Power dissipation in W":"470 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 75 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$8,003.34","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2db047f61c8ddc5782986b48fffc95ae.pdf","sourceUrl":"https://www.se.com/ph/en/product/LV846214/circuit-breaker-masterpact-mtz2-20-h2v-2000-a-4-poles-drawout-without-trip-unit-right-neutral/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LV846214?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to LV846214 in the MasterPact family?","answer":"Within the MasterPact MTZ2 range, the closest form-fit-function equivalent would be a different H2V performance variant at a lower or higher amp rating — but the 2000 A frame, 4-pole drawout, and H2V 100 kA breaking capacity are specific to this order code. No pin-compatible direct drop-in exists; any alternate requires a coordination study."},{"question":"What is LV846214's listed depth?","answer":"The LV846214 has a depth of 403 mm."},{"question":"What is LV846214's listed range?","answer":"The LV846214 belongs to the MasterPacT range."},{"question":"What compliance documentation does this brand provide for LV846214?","answer":"The LV846214 is designed and tested to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitability for isolation is confirmed per EN/IEC 60947-2. Pollution degree 3 per IEC 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846214","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846214 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}