{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846215","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846215","canonicalUrl":"https://aoctrl.com/schneider/LV846215","factsUrl":"https://aoctrl.com/api/mcp/products/LV846215","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ2, LV846215, 4P drawout circuit breaker, 2500 A at 40 °C, H2V 100 kA 415 V AC performance.","salesMarkdown":"## MasterPact MTZ2 2500 A — what this breaker delivers The Schneider Electric LV846215 is a MasterPact MTZ2 drawout circuit breaker rated 2500 A at 40 °C, 4 poles, with H2V performance class delivering 100 kA breaking capacity at 415 V AC. It's built for main incoming or large feeder protection in power distribution — the kind of install where selectivity and fault clearance speed decide uptime. Category B selectivity means it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the plant live. The 25 ms maximum break time and 220 kA making capacity tell you it handles high-energy faults without cascading upstream — critical for switchboard integrity. Rated insulation voltage is 1000 V AC, operational voltage 440 V AC, with impulse withstand at 12 kV. The short-time withstand rating (Icw) holds 100 kA for 1 second — enough for full-selectivity schemes with downstream breakers clearing in their own time band. ## Drawout mounting and panel integration Drawout chassis means the breaker slides out for inspection or replacement without disturbing the bus connections — a standard requirement for main breakers in industrial switchgear. Mounting support is rails or base plate; connection pitch is 115 mm. Dimensions: 556 mm wide, 439 mm high, 403 mm deep. That depth matters when you're laying out the cabinet — make sure the drawout rail has clearance for the full travel. IP30 protection is typical for indoor switchgear; no special sealing for washdown environments. Neutral position is right. Operating altitude 0–2000 m without derating, 2000–5000 m with derating. Ambient temperature range: -25 to 70 °C operating, -40 to 85 °C storage. Power dissipation at rated current is 600 W — factor that into the switchgear ventilation calculation.","metaTitle":"Schneider Electric LV846215 MasterPact MTZ2 2500 A Circuit B","metaDescription":"Schneider Electric LV846215 MasterPact MTZ2 drawout circuit breaker, 2500 A rated current, 100 kA breaking capacity at 440 V AC. Current lifecycle stage. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"403 mm","Range":"MasterPacT","Width":"556 mm","title":"LV846215","Height":"439 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker frame, MasterPact MTZ2 25H2V drawout for MicroLogic X, 2500A, 100kA/415VAC (Icu/Icw), 4P right neutral","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting mode":"Drawout","Sensor rating":"1250 A 1600 A 2000 A 2500 A","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H2V 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ2 25 H2V","Poles description":"4P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"2500 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"15000 cycles with periodic preventive maintenance","Power dissipation in W":"600 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 75 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$11,204.46","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8dd93ba5bab1576f152d3c0f93e5359a.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV846215/circuit-breaker-frame-masterpact-mtz2-25h2v-drawout-for-micrologic-x-2500a-100ka-415vac-icu-icw-4p-right-neutral/"},"ai":{"faq":[{"question":"What is the breaking capacity of LV846215?","answer":"The H2V performance class delivers 100 kA rated service breaking capacity (Ics) at 440 V AC 50/60 Hz, and 100 kA at 220/415 V AC. The rated short-circuit making capacity (Icm) is 220 kA at 440 V AC."},{"question":"What standards does LV846215 comply with?","answer":"Compliant with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitability for isolation is confirmed per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846215","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846215 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}