{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846216","canonicalUrl":"https://aoctrl.com/schneider/LV846216","factsUrl":"https://aoctrl.com/api/mcp/products/LV846216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MasterPact MTZ2, LV846216, drawout circuit breaker, 4P, 3200 A at 40 °C, 100 kA Ics at 440 V AC, H2V performance.","salesMarkdown":"The LV846216 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, part of the MasterPacT range. It's a 4-pole, 3200 A rated device (at 40 °C) built for power distribution protection in commercial and industrial switchboards. The H2V performance class delivers 100 kA Ics at 440 V AC — that's the service breaking capacity it can interrupt and then be reclosed without refurbishment, which matters for continuity in critical feeders. Rated current is 3200 A at 40 °C ambient. If your switchgear room runs hotter, you'll need to derate — the operating range goes up to 70 °C, but the full 3200 A only holds at 40 °C. The Icw short-time withstand is 100 kA for 0.5 s and 1 s, and 75 kA for 3 s; that tells you the breaker can ride through a delayed trip coordination scheme without damage. Insulation voltage is 1000 V AC, impulse withstand 12 kV, so it's comfortable in 690 V systems with proper coordination, though the operational voltage here is rated at 440 V AC. Electrical durability is 5000 cycles at In under AC-23A (440 V), and 6000 cycles under AC-3. Mechanical durability is 15,000 cycles with periodic preventive maintenance. That's typical for a drawout breaker this size — it's not a daily-switching device; it's a protection and isolation device for a main or large feeder. The maximum breaking time is 25 ms, closing response 70 ms, so it clears faults fast enough for selective coordination. This is a drawout breaker — the chassis stays wired in the switchboard, and the breaker element slides in and out for maintenance or replacement without disturbing the power connections. It mounts on rails or a base plate, with a 115 mm connection pitch. Both front and rear connections are available for upside and downside terminations, giving flexibility in busbar layout. Neutral is on the right. The IP30 rating means it's for indoor, clean environments — not washdown, not outdoor.","metaTitle":"LV846216 MasterPact MTZ2 3200 A Circuit Breaker, 100 kA","metaDescription":"LV846216 MasterPact MTZ2 drawout circuit breaker, 3200 A rated current, 100 kA Ics at 440 V AC. Active production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"403 mm","Range":"MasterPacT","Width":"556 mm","title":"LV846216","Height":"439 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"circuit breaker, Masterpact MTZ2 32 H2V, 3200 A, 4 poles, drawout, without trip unit, right neutral","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting mode":"Drawout","Sensor rating":"1600 A 2000 A 2500 A 3200 A","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H2V 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ2 32 H2V","Poles description":"4P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"3200 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"15000 cycles with periodic preventive maintenance","Power dissipation in W":"670 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 75 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$14,805.99","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ede061e18871705ada9ec9834dd703ba.pdf","sourceUrl":"https://www.se.com/il/en/product/LV846216/circuit-breaker-masterpact-mtz2-32-h2v-3200-a-4-poles-drawout-without-trip-unit-right-neutral/"},"ai":{"faq":[{"question":"What is LV846216's rated current and breaking capacity?","answer":"The LV846216 is rated 3200 A at 40 °C, with a service breaking capacity (Ics) of 100 kA at 440 V AC and a rated short-time withstand (Icw) of 100 kA for 1 s."},{"question":"Where can I buy LV846216 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here."},{"question":"What compliance standards does LV846216 meet?","answer":"The LV846216 complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}