{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV846543","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV846543","canonicalUrl":"https://aoctrl.com/schneider/LV846543","factsUrl":"https://aoctrl.com/api/mcp/products/LV846543","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 fixed circuit breaker, LV846543, 1600 A, 3P, 50 kA at 1150 V AC, H10 performance.","salesMarkdown":"The Schneider Electric LV846543 is a MasterPact MTZ2 fixed circuit breaker, 3-pole, rated 1600 A at 40 °C with an ultimate breaking capacity (Icu) of 50 kA at 1150 V AC. It's a Category B breaker (selectivity category per IEC 60947-2), meaning it's designed for main distribution panels where you need discrimination between upstream and downstream faults — a blown feeder shouldn't take the whole board down. Rated operational voltage is 1150 V AC, insulation voltage 1250 V AC, impulse withstand 12 kV. The short-time withstand (Icw) holds 50 kA for up to 3 seconds — that's the rating that matters when coordinating with downstream breakers in a selective scheme. ## Mounting, connections, and panel fit Fixed mounting on rails or base plate. Both upside and downside connections are rear — that's the standard for switchboard lineups where busbars run behind the breaker. Dimensions: 422 mm wide, 352 mm high, 300 mm deep. Connection pitch is 115 mm. IP30 enclosure protection (finger-safe, not water-resistant). Operating altitude 0–2000 m without derating, 2000–5000 m with derating. Mechanical durability is 25,000 cycles with periodic preventive maintenance; electrical durability is 500 cycles at rated voltage. Maximum breaking time 25 ms, closing response 70 ms.","metaTitle":"Schneider Electric LV846543 MasterPact MTZ2 1600A 3P 50kA Ci","metaDescription":"LV846543 MasterPact MTZ2 fixed circuit breaker, 1600 A, 3P, 50 kA at 1150 V AC. Active production. Sourced to order. Standards EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"422 mm","Height":"352 mm","Voltage":"1150 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1250 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Rear","Electrical Life Cycles":"500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2","Mechanical Life Cycles":"25000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$10,650.49 – $11,183.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4bbafd17e8bc80589cce948bc8df799b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV846543/circuit-breaker-frame-masterpact-mtz2-16h10-fixed-for-micrologic-x-1600a-50ka-1150vac-icu-3p/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV846543/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV846543","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV846543 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}