{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847113","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847113","canonicalUrl":"https://aoctrl.com/schneider/LV847113","factsUrl":"https://aoctrl.com/api/mcp/products/LV847113","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ1, LV847113, fixed circuit breaker, 3P, 630 A at 40 °C, H2 50 kA 415 V AC, IP30.","salesMarkdown":"The LV847113 is a fixed-mount MasterPact MTZ1 circuit breaker rated 630 A at 40 °C with an H2 performance class delivering 50 kA breaking capacity at 415 V AC. The 3-pole (3P) configuration suits three-phase power distribution, and the Category B selectivity allows full discrimination with downstream breakers, so a fault on a branch doesn't take the whole panel down. Pollution degree 3 per IEC 60947-1 confirms it handles conductive pollution in industrial enclosures without tracking. Fixed-mount design on rails or base plate, with front and rear connection options on both upside and downside. The 70 mm connection pitch matches standard busbar spacing for panelboard integration. Dimensions: 276 mm wide, 301 mm high, 209 mm deep — plan for a full-height compartment in the switchboard. IP30 protection means it's suitable for enclosed installation; no washdown rating, so keep it inside the cabinet. ## Performance and durability Electrical durability: 3000 cycles at 690 V AC, 6000 cycles at 440 V AC per EN/IEC 60947-2. Mechanical durability: 12,500 cycles with periodic preventive maintenance. The rated short-time withstand current (Icw) is 42 kA for 1 second, giving downstream breakers time to clear a fault before this main breaker trips — that's the selectivity Category B in action. Maximum breaking time is 25 ms, fast enough to limit arc energy in a bolted fault.","metaTitle":"Schneider Electric LV847113 MasterPact MTZ1 630A Circuit Bre","metaDescription":"Schneider Electric LV847113 MasterPact MTZ1 fixed circuit breaker, 630A at 40°C, H2 50kA 415V AC, 3P. Sourced to order against RFQ. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"209 mm","Range":"MasterPacT","Width":"276 mm","title":"LV847113","Height":"301 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker Masterpact MTZ1 06H2 - 630 A - 3P fixed - w/o Micrologic","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ1","Mounting mode":"Fixed","Sensor rating":"400 A 630 A","lifecycle_stage":"current","Connection pitch":"70 mm","Mounting support":"Rails Base plate","Performance type":"H2 50 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ1 06 H2","Poles description":"3P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"630 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"12500 cycles with periodic preventive maintenance","Power dissipation in W":"30 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"50 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"50 kA at 220/415 V AC 50/60 Hz 50 kA at 440 V AC 50/60 Hz 42 kA at 500/525 V AC 50/60 Hz 42 kA at 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"42 kA 0.5 s 42 kA 1 s 24 kA 3 s","[Icm] rated short-circuit making capacity":"105 kA 220/415 V AC at 50/60 Hz 105 kA 440 V AC at 50/60 Hz 88 kA 500/525 V AC at 50/60 Hz 88 kA 660/690 V AC at 50/60 Hz","Integrated instantaneous protection (DIN in kA peak)":"81...99 kA","[Icu] rated ultimate short-circuit breaking capacity":"50 kA at 220/415 V AC 50/60 Hz 50 kA at 440 V AC 50/60 Hz 42 kA at 500/525 V AC 50/60 Hz 42 kA at 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,576.51 – $2,705.33","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/db74eb138a4fe5c263085a488e1e0dd8.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV847113/circuit-breaker-masterpact-mtz1-06h2-630-a-3p-fixed-w-o-micrologic/"},"ai":{"faq":[{"question":"What is the breaking capacity of LV847113?","answer":"The H2 performance class delivers 50 kA Icu at 415 V AC. The rated service breaking capacity (Ics) is also 50 kA at 415 V AC, meaning it can clear a fault at that level and still be usable afterward — not just a one-shot rating."},{"question":"Where can I buy LV847113 and how is it quoted?","answer":"The LV847113 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What compliance documentation does LV847113 carry?","answer":"The breaker complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847113","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847113 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}