{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847276","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847276","canonicalUrl":"https://aoctrl.com/schneider/LV847276","factsUrl":"https://aoctrl.com/api/mcp/products/LV847276","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 32 HA10 switch disconnector, LV847276, 3200 A rated operational current, 1150 V AC, 105 kA Icm, 4 poles, fixed mounting.","salesMarkdown":"The Schneider Electric LV847276 is a MasterPact MTZ2 32 HA10 switch disconnector rated for 3200 A at 1150 V AC, 50/60 Hz, with a short-circuit making capacity of 105 kA peak (Icm) at that voltage. It is a 4-pole, fixed-mount unit with a visible-break indicator and suitability for isolation per EN/IEC 60947-3. This is the part for a main incoming or bus-tie disconnect in a high-current distribution board where you need a single device to handle full-load current and withstand fault energy up to 50 kA for 1 s (Icw). Rated operational current (Ie) of 3200 A AC in utilisation categories AC-23A and AC-3 means this switch disconnector handles motor loads (AC-3) and mixed resistive-inductive loads (AC-23A) up to that current without derating. Short-time withstand (Icw) of 50 kA for 1 s (and 3 s) gives the downstream breakers time to clear before the switch needs to interrupt. ## Deployment context Fixed-mount, 4-pole, 115 mm connection pitch — this lands on a backplate or chassis in a switchboard, not a DIN rail. At 537 mm wide × 352 mm high × 300 mm deep, it needs a substantial compartment — plan the panel layout around its footprint and the cable bending radius for 3200 A terminations.","metaTitle":"Schneider Electric LV847276 MasterPact MTZ2 32 HA10 Switch D","metaDescription":"Schneider Electric LV847276 MasterPact MTZ2 32 HA10 switch disconnector, 3200 A, 1150 V AC, 105 kA Icm, 4P, fixed. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"300 mm","Range":"MasterPact","Width":"537 mm","title":"LV847276","Height":"352 mm","Standards":"EN/IEC 60947-3","description":"Switch disconnector, MasterPact MTZ2 32HA10, 3200A, 105kA/1150VAC 50/60Hz (Icm), 4P, fixed","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","Visible break":"No","lifecycle_stage":"current","Connection pitch":"115 mm","Pollution degree":"3 conforming to EN/IEC 60947-4-1","Network frequency":"50/60 Hz","Performance Level":"HA10","Poles description":"4P","Device application":"Distribution","Utilisation category":"AC-23A AC-3","Electrical durability":"AC-23A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Mechanical durability":"20000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3","IP degree of protection":"IP30","Switch-disconnector name":"MasterPact MTZ2 32 HA10","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN/IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1250 V AC 50/60 Hz conforming to EN/IEC 60947-3","[Ie] rated operational current":"3200 A AC 50/60 Hz 1150 V","[Ue] rated operational voltage":"1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to EN/IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to EN/IEC 60947-3 50 kA during 3 s conforming to EN/IEC 60947-3","[Icm] rated short-circuit making capacity":"105 kA peak 1150 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ebdaf83cff9779f4fbd2e3cf1e3dcd0a.pdf","sourceUrl":"https://www.se.com/be/en/product/LV847276/switch-disconnector-masterpact-mtz2-32ha10-3200a-105ka-1150vac-50-60hz-icm-4p-fixed/"},"ai":{"faq":[{"question":"Where can I buy LV847276 and how do I get a price?","answer":"The LV847276 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to LV847276 in this component family?","answer":"Within the MasterPact MTZ2 family, the LV847276 is a specific rating (3200 A, 4P, fixed, HA10 performance level). A different rating (e.g., 4000 A or 3P variant) would change the footprint or electrical performance — no direct pin-compatible drop-in exists without re-engineering the busbar and enclosure."},{"question":"What is LV847276's listed depth (300 mm) on this component line?","answer":"The LV847276 has a depth of 300 mm, which is the dimension from the mounting surface to the front of the device (excluding operating handle projection)."},{"question":"What is LV847276's listed range (MasterPact) on this component line?","answer":"The LV847276 belongs to the MasterPact range, specifically the MasterPact MTZ2 32 HA10 switch-disconnector series."},{"question":"What compliance documentation does this brand provide for LV847276 (RoHS, REACH, UL, IEC)?","answer":"The LV847276 is designed and tested to EN/IEC 60947-3. For RoHS, REACH, and UL declarations, the manufacturer provides compliance documentation on request — these are not listed in the standard product spec but are typically available through the brand's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847276","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847276 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}