{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847283WW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847283WW","canonicalUrl":"https://aoctrl.com/schneider/LV847283WW","factsUrl":"https://aoctrl.com/api/mcp/products/LV847283WW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MicroLogic 5.0 Xi control unit, LV847283WW, electronic LSI trip unit with LCD display, power metering, wired control, 4P 3P.","salesMarkdown":"## What this control unit does in the panel The Schneider Electric LV847283WW is a MicroLogic 5.0 Xi electronic control unit for MasterPacT circuit breakers. It provides LSI protection (long-time, short-time, instantaneous) per ANSI 49/50/51, plus full power metering on a 128 x 96 pixel LCD display. This is the brain that decides when to trip and what the load is doing — not just a breaker accessory, but the panel's primary protection and monitoring node. The unit measures current (I1, I2, I3, Iavg, IN RMS, Ig RMS), voltage (V12, V23, V31, V1N, V2N, V3N), active/reactive/apparent power and energy, power factor, frequency, THD (current and voltage), unbalance, and earth leakage. Accuracy hits Class 0.5 for voltage and Class 1 for active energy — good enough for sub-metering and energy allocation without a separate power meter. Rated operational voltage is 690 V AC +/-10%, with measurement voltage range 208-828 V AC phase-to-phase and 120-480 V AC phase-to-neutral at 50/60 Hz. The trip unit ratings span 400 A to 6300 A depending on the breaker frame (MTZ1, MTZ2, MTZ3). For a distribution board feeding a 2000 A main, this control unit gives you the protection curves and the data logging in one package. ## Mounting and integration — what fits where Fixed mounting, indoor use only. This is a control unit that plugs into the MasterPacT breaker cradle — no DIN rail, no panel cutout. The wired control connection means you run the control wiring to the breaker's auxiliary contacts and shunt trip, not a separate relay panel. The unit supports multiple neutral protection configurations: 1 x Ir (4P 4d), 0.5 x Ir (4P 3d + N/2), 1.6 x Ir (4P 3d + OSN), or no protection (4P 3d). That covers solidly-grounded, impedance-grounded, and corner-grounded delta systems. If you're wiring a 4P 3d + N/2 setup, the neutral CT ratio is half the phase CT — the control unit handles the math internally. Zone selective interlocking (ZSI) is included. That means this unit communicates trip status with upstream and downstream breakers to clear a fault in the shortest time without losing coordination. In a multi-level distribution system, ZSI keeps the lights on for the rest of the plant when a feeder faults. ## Standards and compliance — what the approvals mean The control unit carries approvals under EN/IEC 60947-2 (circuit breakers), EN/IEC 60092-202 (marine electrical), EN/IEC 60947-1 (general rules), EN/IEC 60255-1 (measuring relays), and EN/IEC 61010-1 (safety for electrical measurement). The marine standard (60092-202) means this unit is accepted for shipboard distribution — not just landside. Measurement category IV per IEC 61010-2-30 means it's rated for installation at the service entrance, not just downstream sub-panels. EMC compliance covers electrostatic discharge (IEC 61000-4-2), radiated fields (IEC 61000-4-3), fast transients (IEC 61000-4-4), surge 1.2/50 µs (IEC 61000-4-5), conducted RF (IEC 61000-4-6), and conducted/radiated emissions Class A per CISPR 22. That's the full industrial immunity suite — no extra filtering needed for a typical switchboard environment. Operating altitude up to 5000 m with voltage derating to 560 V AC. Relative humidity 95% at 55°C per IEC 60068-2-30. Note the environmental characteristic: not approved for wet location use per IEC 61010-1 — keep this unit dry inside the enclosure.","metaTitle":"Schneider LV847283WW MicroLogic 5.0 Xi Control Unit, MasterP","metaDescription":"Schneider Electric LV847283WW MicroLogic 5.0 Xi control unit for MasterPacT breakers. LSI protection, metering, LCD display. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Poles":"4","Voltage":"690 V AC, +/- 10 %","Application":"Equipment protection, monitoring and control","Control Type":"Wired control","Display Type":"LCD display - 128 x 96 pixels","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Main Product Or Component Type":"Control unit","Ambient Air Temperature Operation":"-25...70 °C (operating) -35 °C (for start-up of product)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/653202cb3398f615074daba03a903445.pdf","sourceUrl":"https://www.se.com/th/en/product/LV847283WW/micrologic-5-0xi-control-unit-no-wireless-masterpact-mtz1-mtz2-mtz3-fixed-circuit-breakers-lsi-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV847283WW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847283WW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847283WW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}