{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847292WW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847292WW","canonicalUrl":"https://aoctrl.com/schneider/LV847292WW","factsUrl":"https://aoctrl.com/api/mcp/products/LV847292WW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT, MicroLogic 6.0 Xi control unit, LSIG protection, 3P 4P, drawout, LCD display, 690 V AC.","salesMarkdown":"## MicroLogic 6.0 Xi control unit for MasterPacT drawout breakers The Schneider Electric LV847292WW is a MicroLogic 6.0 Xi electronic control unit for the MasterPacT range of drawout air circuit breakers. It provides LSIG protection — long-time, short-time, instantaneous, and ground-fault — with a trip unit rating selectable from 400 A up to 1600 A. The drawout mounting means the control unit and its breaker can be racked out for maintenance without disturbing line-side connections, a key feature for switchboard installations where uptime matters. ## What the LSIG protection scheme means for coordination LSIG covers the full protection curve: overload (long-time, ANSI 49), short-time delay (ANSI 51), instantaneous (ANSI 50), and earth fault (ANSI 51N). The long-time delay is adjustable in 0.5 s steps, which lets the engineer tune selectivity with downstream breakers. Zone selective interlocking (ZSI) is built in — when multiple MasterPacT breakers are linked, the faulted unit trips instantaneously while upstream units hold, reducing arc-flash energy at the fault point. For a site electrical engineer reviewing a coordination study, this is the feature that makes the difference between a selective and a cascading trip. ## Metering and display: what you can read from the front panel The 128 x 96 pixel LCD shows a full electrical instrumentation suite: per-phase and average currents, neutral and ground-fault current, phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power and energy, power factor, frequency, demand values, and harmonic distortion (THD) for both current and voltage. Measurement accuracy for current is ±0.5 % over the 40–1600 A range for MTZ1 frames. The control unit also logs events, alarms, maintenance data, and min/max instantaneous values with time stamps. This is not just a trip unit — it replaces a separate power meter in the same drawout cassette. ## Environmental and installation constraints Operating altitude goes to 5000 m with voltage derating above 560 V AC. Humidity tolerance is 95 % at 55 °C. The control unit is not approved for wet locations, so keep it in the dry switchgear room. EMC compliance covers electrostatic discharge, radiated fields, fast transients, surge (1.2/50 µs), and conducted RF, with conducted and radiated emissions at Class A per CISPR 22.","metaTitle":"Schneider Electric LV847292WW MicroLogic 6.0 Xi, MasterPacT,","metaDescription":"Schneider Electric LV847292WW MicroLogic 6.0 Xi control unit for MasterPacT drawout breakers. LSIG protection, 690 V AC, LCD metering. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Poles":"3P 4P","Range":"MasterPacT","title":"LV847292WW","Standards":"EN/IEC 60255-1 EN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 61010-1","description":"MicroLogic 6.0Xi control unit, no wireless, MasterPact MTZ1, drawout circuit breakers, LSIG protections","Control type":"Wired control","Display type":"LCD display - 128 x 96 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage","Mounting mode":"Drawout","Accuracy class":"Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)","Data recording":"Data logs Event logs Alarm logs Time stamping Maintenance logs Min/max of instantaneous values","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51 Earth fault conforming to ANSI 51N","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"400 A 630 A 800 A 1000 A 1250 A 1600 A","Device short name":"MicroLogic 6.0 Xi","Energy management":"Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Measurement voltage":"208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral","Type of measurement":"Power meter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ground-fault pick-up adjustment type":"Adjustable","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","Ground-Fault Time Delay Adjustment Type":"Adjustable","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Instantaneous pick-up adjustment type Ii":"Adjustable","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app","[Ig] ground-fault pick-up adjustment range":"with In > 400 A 0.2...1 x In adjustable in step of 1 or 10 A with In Ig enable on/off","[Ii] instantaneous pick-up adjustment range":"2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off","[tg] Ground-fault time delay adjustment range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","[Li Mode] Instantaneous Delay Adjustment Range":"0 ms in fast 20 ms in standard"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/13b3e2bb538e99e5667e3f26e3f0312a.pdf","sourceUrl":"https://www.se.com/au/en/product/LV847292WW/micrologic-6-0xi-control-unit-no-wireless-masterpact-mtz1-drawout-circuit-breakers-lsig-protections/"},"ai":{"faq":[{"question":"Where can I buy LV847292WW and how do I get a price?","answer":"The LV847292WW is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is LV847292WW's listed poles (3P 4P) on this component line?","answer":"The LV847292WW supports both 3-pole and 4-pole configurations (3P 4P), with protected pole options including 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN."},{"question":"What is LV847292WW's listed range (MasterPacT) on this component line?","answer":"The LV847292WW belongs to the Schneider Electric MasterPacT range of air circuit breakers."},{"question":"What compliance documentation does this brand provide for LV847292WW (RoHS, REACH, UL, IEC)?","answer":"The LV847292WW is designed and tested to EN/IEC 60255-1, EN/IEC 60947-2, EN/IEC 60092-202, EN/IEC 60947-1, and EN/IEC 61010-1. Measurement category is IV per IEC 61010-2-30, overvoltage category IV per IEC 61010-1. EMC compliance includes CISPR 22 Class A emissions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847292WW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847292WW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}