{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847411","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847411","canonicalUrl":"https://aoctrl.com/schneider/LV847411","factsUrl":"https://aoctrl.com/api/mcp/products/LV847411","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ1 drawout, XF closing voltage release with diagnostics & communication, 12 VDC, obsolete.","salesMarkdown":"LV847411 is a Schneider Electric MasterPact MTZ1 drawout closing voltage release (XF diag & com type) that operates on a 12 VDC supply. It signals error, electrical push-button activation, coil power, and ready-to-close/open status. Maximum response time is 65 ms on closing for MasterPact MTZ1 frames. The 12 VDC supply (0.85–1.1 Un on closing threshold) matches low-voltage control schemes common in industrial panels where a separate 12 VDC bus powers trip/close coils. Holding power consumption of 4.5 W keeps the burden on the DC supply modest. The 65 ms max response time on MTZ1 drawout breakers is fast enough for most coordination schemes — selectivity curves are unaffected at this closing speed. ## Deployment Context Designed for drawout MasterPact MTZ1 circuit breakers — the communicating variant integrates with building management or SCADA systems via the XF diagnostics interface. Mounted inside the breaker cradle, it replaces the standard closing coil when remote status and diagnostics are required.","metaTitle":"LV847411 MasterPact MTZ1 Voltage Release, 12 VDC, Obsolete","metaDescription":"LV847411 XF closing voltage release for MasterPact MTZ1 drawout breakers. 12 VDC supply, 65 ms max response. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Air Circuit Breakers"],"specifications":{"Range":"MasterPact","Control Type":"Communicating","lifecycle_stage":"current","Device short name":"XF diag & com","Device Application":"Control","Signalling function":"Error Electrical push-button activated Coil powered Ready to close or open","Voltage release type":"Closing coil","Maximum response time":"65 ms on closing MasterPact MTZ1","Nbr. of units in pkg.":"1","Holding power consumption":"4.5 W","Product or Component Type":"Voltage release","[Un] voltage power supply":"12 V DC","Threshold tripping voltage":"0.85...1.1 Un on closing","Circuit breaker mounting mode":"Drawout"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51f3f327032a7fc46f5c45ad8e561291.pdf","sourceUrl":"https://www.se.com/us/en/product/LV847411/xf-closing-voltage-release-diagnostics-and-communicating-masterpact-mtz1-drawout-12-vdc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV847411/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LV847411?","answer":"Pricing and stock are confirmed at quote time against an RFQ. Because the part is obsolete, availability varies — we check our multi-source network on each request."},{"question":"What is LV847411's listed range (MasterPact) on this component line?","answer":"The range is MasterPact — specifically the MTZ1 drawout frame. This is the communicating closing voltage release variant (XF diag & com)."},{"question":"What is LV847411's listed control type (Communicating) on this component line?","answer":"Control type is Communicating — the XF variant includes diagnostics and communication functions alongside the closing coil, enabling remote status monitoring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847411","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847411 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}