{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV847604","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV847604","canonicalUrl":"https://aoctrl.com/schneider/LV847604","factsUrl":"https://aoctrl.com/api/mcp/products/LV847604","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MicroLogic 7.0 X control unit, LV847604, electronic trip unit with LSIV protection, LCD display, 4P 3P poles, rated for 400–3200 A frames.","salesMarkdown":"## What this control unit does The LV847604 is a MicroLogic 7.0 X electronic control unit for Schneider MasterPacT circuit breakers. It's the brain that handles equipment protection, monitoring, and control inside the breaker — not a standalone device. You slot it into a compatible MasterPacT frame (trip unit ratings from 400 A up to 3200 A) and it takes over the trip logic, metering, and communications. Protection functions are LSIV: long-time overload (ANSI 49), instantaneous short-circuit (ANSI 50), short-time short-circuit (ANSI 51), and earth-leakage (ANSI 51G). That covers the full selectivity stack for a distribution feeder — you can coordinate downstream breakers with the short-time delay and ZSI (zone selective interlocking) to clear faults fast without tripping the whole bus. It measures everything you'd expect from a power meter: per-phase and average RMS current, neutral and ground fault current, phase-to-phase and phase-to-neutral voltage, active/reactive/apparent power, power factor, energy in/out/total, frequency, THD for current and voltage, unbalance, and demand values. Accuracy on current and voltage is ±0.5 %, active energy ±1 % — Class 1 for billing-grade energy logging. Mounts inside the MasterPacT breaker — no DIN rail, no separate enclosure. The 128 x 96 pixel LCD gives you local readout of all metered values and event logs without needing to plug in a laptop. Communication ports are Bluetooth 4.0 LE (30 kbit/s), NFC (28.8 kbaud), and USB (115 kbaud) for local configuration and data pull. No onboard Ethernet or fieldbus — that comes via a separate communication module on the breaker. Indoor use only, wet locations not approved. Operating altitude up to 5000 m with voltage derating above 2000 m (560 V AC at max altitude).","metaTitle":"Schneider LV847604 MicroLogic 7.0 X Control Unit, MasterPacT","metaDescription":"Schneider Electric LV847604 MicroLogic 7.0 X control unit for MasterPacT breakers. LSIV protection, LCD display, IEC 60947 compliant. Current lifecycle. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Poles":"4","Voltage":"600 V AC, +/- 10 %","Application":"Equipment protection, monitoring and control","Display Type":"LCD display - 128 x 96 pixels","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Main Product Or Component Type":"Control unit","Ambient Air Temperature Operation":"-25...70 °C (operating) -35 °C (for start-up of product)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,896.07","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57e7bab0a520caf605bfdcb093a721d2.pdf","sourceUrl":"https://www.se.com/za/en/product/LV847604/micrologic-7-0x-control-unit-masterpact-mtz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV847604/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV847604","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV847604 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}