{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848060","canonicalUrl":"https://aoctrl.com/schneider/LV848060","factsUrl":"https://aoctrl.com/api/mcp/products/LV848060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 20 H1, fixed circuit breaker, 4P, 2000 A at 40 °C, 66 kA breaking at 415 V AC, IP30.","salesMarkdown":"## MasterPact MTZ2 20 H1 — 2000 A fixed breaker, Category B selectivity The Schneider Electric LV848060 is a MasterPact MTZ2 20 H1 fixed-mount circuit breaker, 4-pole, rated 2000 A continuous at 40 °C. This is the H1 performance variant, delivering 66 kA rated service breaking capacity (Ics) at 415 V AC — the same figure holds across 440 V, 500/525 V, and 660/690 V AC, so you don't lose headroom at higher voltages. Category B selectivity (per EN/IEC 60947-2) means it's designed for full discrimination with downstream breakers, critical for minimizing outage scope in a distribution board. Rated short-time withstand (Icw) is 66 kA for 0.5 s and 1 s, dropping to 36 kA at 3 s — that 1-second window covers most delayed-tripping coordination schemes. Making capacity (Icm) hits 145 kA at 415 V, confirming the breaker can close into a full fault without contact welding. Mechanical durability is 20,000 cycles with periodic preventive maintenance; electrical endurance under AC-3 motor-switching duty is 6,000 cycles at 690 V. Fixed-mount chassis, 352 mm high × 537 mm wide × 300 mm deep. Connection pitch is 115 mm. Upside and downside connections accept both front and rear terminations, giving flexibility for busbar or cable entry in a switchboard. Mounts on rails or a base plate — typical for a dedicated MCC or distribution section. Also complies with IEC 61557-12 for insulation monitoring. Rated insulation voltage (Ui) 1000 V AC, rated impulse withstand (Uimp) 12 kV.","metaTitle":"Schneider Electric LV848060 MasterPact MTZ2 20 H1, 2000 A, 4","metaDescription":"Schneider Electric LV848060 MasterPact MTZ2 20 H1 circuit breaker. 2000 A rated current, 4-pole fixed mount, 66 kA breaking capacity at 415 V AC. EN/IEC 60947 compliant. Current pr","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"537 mm","Height":"352 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Mechanical Life Cycles":"20000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c829749e6b742522cbeb77a3fc17c208.pdf","sourceUrl":"https://www.se.com/au/en/product/LV848060/circuit-breaker-frame-masterpact-mtz2-20h1-fixed-for-micrologic-x-2000a-66ka-415vac-icu-4p-right-neutral/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848060/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}