{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848067","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848067","canonicalUrl":"https://aoctrl.com/schneider/LV848067","factsUrl":"https://aoctrl.com/api/mcp/products/LV848067","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2, LV848067, fixed-mount air circuit breaker, 4P, 2000 A at 40 °C, H2 100 kA at 415 V AC, without control unit.","salesMarkdown":"The Schneider Electric LV848067 is a MasterPact MTZ2 20 H2 fixed-mount air circuit breaker, 4-pole, rated 2000 A at 40 °C. The 2000 A sensor rating means the breaker's electronic trip unit reads current through that window; the frame itself handles the full 2000 A continuous without derating up to 40 °C ambient. This is a power distribution protection device, not a motor-circuit breaker. The 4-pole version with neutral on the right suits TN-S or TN-C-S systems where you switch the neutral. That's the ultimate short-circuit capacity — the breaker can interrupt one fault at that level and still be serviceable afterward. The service breaking capacity Ics matches Icu at 415 V (100 kA) and at 440 V (100 kA), meaning after clearing a fault at those voltages the breaker is rated to carry full current again. At 690 V, Ics drops to 85 kA. The making capacity Icm hits 220 kA at 415 V — that's the peak let-through the contacts must close onto and latch against. For selective coordination, the short-time withstand Icw is 85 kA for 0.5 s and 1 s, and 75 kA for 3 s, which gives downstream breakers time to clear a fault before this upstream device trips. Maximum breaking time is 25 ms, closing response 70 ms. The 12 kV impulse withstand covers surge coordination per IEC 60947-1. ## Environmental limits and durability Altitude: full rating up to 2000 m, derated above that to 5000 m. Electrical durability varies by duty: 8000 cycles at 440 V AC under EN/IEC 60947-2, 6000 cycles at 690 V AC under the same standard, and 6000 to 8000 cycles for AC-23A switching duties per EN/IEC 60947-3. Power dissipation is 250 W — factor that into enclosure ventilation or air conditioning for a multi-breaker lineup.","metaTitle":"Schneider Electric LV848067 MasterPact MTZ2 20 H2, 2000 A, 4","metaDescription":"Schneider Electric LV848067 MasterPact MTZ2 circuit breaker, 2000 A rated current, 4 poles, H2 100 kA at 415 V AC, fixed mounting. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"300 mm","Range":"MasterPacT","Width":"537 mm","title":"LV848067","Height":"352 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker frame, MasterPact MTZ2 20H2 fixed for MicroLogic X, 2000A, 100kA/415VAC (Icu), 4P right neutral","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting mode":"Fixed","Sensor rating":"1000 A 1250 A 1600 A 2000 A","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H2 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ2 20 H2","Poles description":"4P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"2000 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 6000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 8000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 6000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 8000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles with periodic preventive maintenance","Power dissipation in W":"250 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"85 kA 0.5 s 85 kA 1 s 75 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 187 kA 500/525 V AC at 50/60 Hz 187 kA 660/690 V AC at 50/60 Hz","Integrated instantaneous protection (DIN in kA peak)":"171...209 kA","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/98e24ae25d80455b901162a3da33a1e6.pdf","sourceUrl":"https://www.se.com/au/en/product/LV848067/circuit-breaker-frame-masterpact-mtz2-20h2-fixed-for-micrologic-x-2000a-100ka-415vac-icu-4p-right-neutral/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LV848067?","answer":"The LV848067 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is LV848067's listed depth?","answer":"The LV848067 has a depth of 300 mm. Combined with its 537 mm width and 352 mm height, this sets the minimum enclosure size for fixed mounting."},{"question":"What compliance documentation does LV848067 carry?","answer":"The LV848067 is designed to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2 and rated for pollution degree 3 per IEC 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848067","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848067 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}