{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848103","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848103","canonicalUrl":"https://aoctrl.com/schneider/LV848103","factsUrl":"https://aoctrl.com/api/mcp/products/LV848103","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ3, LV848103, fixed 4P circuit breaker, 4000 A at 40 °C, H2 performance 150 kA at 415 V AC, rear connection.","salesMarkdown":"The Schneider Electric LV848103 is a MasterPact MTZ3 fixed-mount circuit breaker, 4 poles, rated 4000 A at 40 °C. Rear connection top and bottom, so it's built for switchboard bus-stack integration, not standalone panel mounting. Category B selectivity means this breaker is designed for full discrimination with downstream devices — a fault on a branch won't take the main feeder out. The Icw short-time withstand is 100 kA for up to 3 seconds, which gives downstream breakers time to clear before the main trips. That's the spec that matters for coordination studies in a distribution board. Rated insulation voltage is 1000 V AC, operational voltage 690 V AC. Impulse withstand at 12 kV. ## Physical fit Fixed mounting on rails or base plate. Width 997 mm, height 352 mm, depth 300 mm. Connection pitch 230 mm. That depth is the overall front-to-back dimension including the mechanism — verify cabinet depth before specifying. Neutral position is right. ## Standards and documentation Compliant with EN/IEC 60947-1, EN/IEC 60947-2, and Annex H for selective coordination. Also meets IEC 61557-12 for power metering. Suitability for isolation confirmed per EN/IEC 60947-2. IP30 protection — not for washdown, but fine in a clean switchroom.","metaTitle":"Schneider Electric LV848103 MasterPact MTZ3 4000 A Circuit B","metaDescription":"Schneider Electric LV848103 MasterPact MTZ3 4000 A fixed circuit breaker, H2 150 kA at 415 V AC, 4P, rear connection. Active production, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"997 mm","Height":"352 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"230 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Rear","Mechanical Life Cycles":"10000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/627bd98c36eb879a65b1677be01f90e3.pdf","sourceUrl":"https://www.se.com/th/en/product/LV848103/circuit-breaker-frame-masterpact-mtz3-40h2-fixed-for-micrologic-x-4000a-150ka-415vac-icu-4p-right-neutral/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848103/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848103","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848103 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}