{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848180","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848180","canonicalUrl":"https://aoctrl.com/schneider/LV848180","factsUrl":"https://aoctrl.com/api/mcp/products/LV848180","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2, fixed circuit breaker, 4P, 1600 A at 40 °C, H2 100 kA at 415 V AC, push-button control, without control unit.","salesMarkdown":"The Schneider Electric LV848180 is a MasterPact MTZ2 fixed-mount circuit breaker, 4-pole, rated 1600 A at 40 °C, with an H2 performance class delivering 100 kA breaking capacity at 415 V AC. It's a Category B breaker (fully selective per EN/IEC 60947-2), meaning it coordinates with downstream devices to isolate only the faulted branch — critical for maintaining uptime on a plant distribution bus. Rated operational voltage is 690 V AC, with an insulation voltage of 1000 V AC and impulse withstand of 12 kV — this breaker is built for 480/600 V class switchgear, not just 240 V panels. Short-time withstand (Icw) is 85 kA for 1 second, which is what lets it ride through a downstream fault and stay closed for selective coordination. Power dissipation is 170 W — plan for ventilation in the enclosure. Mechanical durability is 25,000 cycles with periodic preventive maintenance; electrical durability is 10,000 cycles at 440 V AC under EN/IEC 60947-2. For motor-switching duty (AC-3), it's rated 6,000 cycles at 440/690 V. Maximum break time is 25 ms, close time 70 ms — fast enough for most coordination schemes. This breaker ships without a control unit and uses push-button control. It accepts sensor ratings from 800 A through 1600 A, so you can fit it with a lower-rated sensor if the load doesn't need the full frame. Neutral is on the right. Mounting is fixed on rails or a base plate. Altitude rating is 0–2000 m without derating, 2000–5000 m with derating.","metaTitle":"Schneider Electric LV848180 MasterPact MTZ2 1600 A Circuit B","metaDescription":"Schneider Electric LV848180 MasterPact MTZ2 4P fixed circuit breaker, rated 1600 A at 40 °C, H2 100 kA at 415 V AC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"300 mm","Range":"MasterPacT","Width":"537 mm","title":"LV848180","Height":"352 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker MTZ2 16H2 - 1600 A - 4P fixed - right neutral - w/o Micrologic","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting mode":"Fixed","Sensor rating":"800 A 1000 A 1250 A 1600 A","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H2 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ2 16 H2","Poles description":"4P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"1600 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"25000 cycles with periodic preventive maintenance","Power dissipation in W":"170 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"85 kA 0.5 s 85 kA 1 s 50 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 187 kA 500/525 V AC at 50/60 Hz 187 kA 660/690 V AC at 50/60 Hz","Integrated instantaneous protection (DIN in kA peak)":"171...209 kA","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/04e0add4608e69ea7926a3e37734508b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848180/circuit-breaker-mtz2-16h2-1600-a-4p-fixed-right-neutral-w-o-micrologic/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LV848180?","answer":"Submit an RFQ for the LV848180. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is LV848180's rated current and breaking capacity?","answer":"The LV848180 is rated 1600 A at 40 °C with an H2 breaking capacity of 100 kA at 415 V AC. Service breaking capacity (Ics) is 100 kA at 440 V AC."},{"question":"What compliance standards does LV848180 meet?","answer":"The LV848180 is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2."},{"question":"What is the closest alternative to LV848180 in the MasterPact family?","answer":"Within the MasterPact MTZ2 range, the LV848180 is the 4-pole, 1600 A, H2 (100 kA) fixed-mount variant. A lower-amp variant (e.g., 800 A frame) or a different performance class (H1, H3) would be a different order code. No direct pin-compatible alternative exists; the frame size and mounting pattern are specific to this rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848180","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848180 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}