{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848180","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848180","canonicalUrl":"https://aoctrl.com/schneider/LV848180","factsUrl":"https://aoctrl.com/api/mcp/products/LV848180","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2, fixed circuit breaker, 4P, 1600 A at 40 °C, H2 100 kA at 415 V AC, push-button control, without control unit.","salesMarkdown":"The Schneider Electric LV848180 is a MasterPact MTZ2 fixed-mount circuit breaker, 4-pole, rated 1600 A at 40 °C, with an H2 performance class delivering 100 kA breaking capacity at 415 V AC. It's a Category B breaker (fully selective per EN/IEC 60947-2), meaning it coordinates with downstream devices to isolate only the faulted branch — critical for maintaining uptime on a plant distribution bus. Rated operational voltage is 690 V AC, with an insulation voltage of 1000 V AC and impulse withstand of 12 kV — this breaker is built for 480/600 V class switchgear, not just 240 V panels. Short-time withstand (Icw) is 85 kA for 1 second, which is what lets it ride through a downstream fault and stay closed for selective coordination. Power dissipation is 170 W — plan for ventilation in the enclosure. Mechanical durability is 25,000 cycles with periodic preventive maintenance; electrical durability is 10,000 cycles at 440 V AC under EN/IEC 60947-2. For motor-switching duty (AC-3), it's rated 6,000 cycles at 440/690 V. Maximum break time is 25 ms, close time 70 ms — fast enough for most coordination schemes. This breaker ships without a control unit and uses push-button control. It accepts sensor ratings from 800 A through 1600 A, so you can fit it with a lower-rated sensor if the load doesn't need the full frame. Neutral is on the right. Mounting is fixed on rails or a base plate. Altitude rating is 0–2000 m without derating, 2000–5000 m with derating.","metaTitle":"Schneider Electric LV848180 MasterPact MTZ2 1600 A Circuit B","metaDescription":"Schneider Electric LV848180 MasterPact MTZ2 4P fixed circuit breaker, rated 1600 A at 40 °C, H2 100 kA at 415 V AC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"537 mm","Height":"352 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/04e0add4608e69ea7926a3e37734508b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848180/circuit-breaker-mtz2-16h2-1600-a-4p-fixed-right-neutral-w-o-micrologic/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848180/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848180","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848180 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}