{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848194","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848194","canonicalUrl":"https://aoctrl.com/schneider/LV848194","factsUrl":"https://aoctrl.com/api/mcp/products/LV848194","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ3, LV848194, fixed 4-pole circuit breaker, 4000 A rated current, H1 100 kA breaking capacity at 415 V AC, Category B, rear connection.","salesMarkdown":"The LV848194 is a MasterPact MTZ3 fixed-mount circuit breaker rated 4000 A at 40 °C, 4 poles, with an H1 performance class delivering 100 kA Icu/Ics across the full voltage range up to 690 V AC. That 100 kA Ics at 440 V means it clears a fault and can be immediately reclosed without inspection — a key spec for selective coordination in industrial distribution where you need Category B selectivity (the breaker itself is rated Category B per IEC 60947-2). The Icw of 100 kA for 3 seconds tells you it withstands delayed clearing from downstream breakers, so it works as a main or tie breaker in a switchboard where fault-rating coordination is required. The 220 kA making capacity (Icm) covers the worst-case peak asymmetrical fault on a 415 V system. The 25 ms maximum breaking time and 80 ms closing response time are the numbers to plug into your arc-flash study. ## Deployment context The 260 W power dissipation at rated current matters for enclosure cooling calculations; factor that into the switchgear ventilation design. The H1 performance class is Schneider's designation for 100 kA Icu at 415 V; the Ics equals Icu at all voltage levels up to 690 V, which is unusual and valuable for coordination studies.","metaTitle":"Schneider MasterPact MTZ3 LV848194, 4000 A 4P H1 100 kA","metaDescription":"LV848194 MasterPact MTZ3 fixed circuit breaker, 4000 A, 4 poles, H1 100 kA at 415 V AC, Category B. Sourced to order against RFQ. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"300 mm","Width":"997 mm","Height":"352 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"230 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Rear","Mechanical Life Cycles":"10000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/059ec40399b7f1ccd29caab62b781823.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848194/circuit-breaker-mtz3-40h1-4000-a-4p-fixed-right-neutral-w-o-micrologic/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848194/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848194","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848194 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}