{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848195","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848195","canonicalUrl":"https://aoctrl.com/schneider/LV848195","factsUrl":"https://aoctrl.com/api/mcp/products/LV848195","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ3, type MTZ3 50 H1, fixed-mount 4P circuit breaker, 5000 A at 40 °C, H1 100 kA 415 V AC performance class.","salesMarkdown":"## What the 5000 A and 100 kA ratings mean for your switchboard The LV848195 is a MasterPacT MTZ3 50 H1 fixed-mount circuit breaker rated 5000 A at 40 °C with an H1 performance class delivering 100 kA Icu at 415 V AC. That 100 kA holds across the full operating voltage range up to 690 V AC, so the breaker clears a fault at the same interrupting capacity whether it sits on a 415 V or 690 V bus. The Icw rating of 100 kA for 3 s means it withstands a delayed trip coordination window without damage — essential for selective coordination (Category B per IEC 60947-2) where downstream breakers clear first and this unit holds in. The 420 W power dissipation at rated current matters for enclosure thermal design — a switchboard housing this unit needs ventilation or forced cooling to stay within the -25 to 70 °C operating range. ## Standards compliance and isolation suitability ## Physical integration — fixed-mount, rear-connected, 4P Fixed-mount design with rear connection on both the line and load sides. The 997 mm width, 352 mm height, and 300 mm depth define the panel cutout and busbar layout. Connection pitch is 230 mm, which matches standard MasterPacT busbar systems. Mounting support is rails or base plate — the breaker bolts into a dedicated cradle, not a DIN rail. The neutral pole is on the right (4P, neutral right), so busbar phasing must follow that orientation. ## Durability and operating conditions Mechanical durability is 10,000 cycles with periodic preventive maintenance. Electrical durability under AC-3 switching duty is 6000 cycles at 440/690 V AC. IP30 protection means it is not washdown-rated — install inside a switchboard enclosure.","metaTitle":"Schneider Electric LV848195 MasterPacT MTZ3 50 H1, 5000 A, 1","metaDescription":"Schneider Electric LV848195 MasterPacT MTZ3 50 H1 circuit breaker, 5000 A rated current, H1 100 kA at 415 V AC. Current lifecycle status, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"300 mm","Range":"MasterPacT","Width":"997 mm","title":"LV848195","Height":"352 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker MTZ3 50H1 - 5000 A - 4P fixed - right neutral - w/o Micrologic","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ3","Mounting mode":"Fixed","Sensor rating":"2500 A 3200 A 4000 A 5000 A","lifecycle_stage":"current","Connection pitch":"230 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H1 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ3 50 H1","Poles description":"4P","Upside connection":"Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"5000 A at 40 °C","Downside connection":"Rear","Selectivity category":"Category B","Electrical durability":"AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"10000 cycles with periodic preventive maintenance","Power dissipation in W":"420 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"80 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz 100 kA at 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 100 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 220 kA 500/525 V AC at 50/60 Hz 220 kA 660/690 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz 100 kA at 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cb1695a7df43e3e35eeadfceeff2f8aa.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848195/circuit-breaker-mtz3-50h1-5000-a-4p-fixed-right-neutral-w-o-micrologic/"},"ai":{"faq":[{"question":"What is the breaking capacity of LV848195?","answer":"The H1 performance class delivers 100 kA Icu at 415 V AC, and that 100 kA holds across the full operating voltage range up to 690 V AC. The Icw is 100 kA for 3 s, supporting selective coordination."},{"question":"Where can I buy LV848195?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does LV848195 comply with?","answer":"Certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitable for isolation per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848195","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848195 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}