{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848196","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848196","canonicalUrl":"https://aoctrl.com/schneider/LV848196","factsUrl":"https://aoctrl.com/api/mcp/products/LV848196","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ3, LV848196, 4P fixed circuit breaker, 6300 A at 40 °C, H1 performance 100 kA at 415 V AC, rear connections.","salesMarkdown":"## 6300 A fixed-mount air breaker — selectivity and SCCR headroom The Schneider Electric LV848196 is a MasterPact MTZ3 63 H1 fixed-mount air circuit breaker rated 6300 A at 40 °C, 4 poles, with rear upper and lower connections. The Ics (service breaking capacity) matches at 100 kA across 220/415 V through 660/690 V, so the breaker remains usable after a fault at those levels. Icw short-time withstand is also 100 kA for 3 seconds, giving full selectivity with downstream devices — a Category B breaker per IEC 60947-2. For a 6300 A main, that means a fault on a feeder branch won't trip the main, keeping the rest of the plant online. The operating range spans -25 to 70 °C, with full rated current at 40 °C; above that, standard thermal derating applies. Altitude operation is 0–2000 m without derating, 2000–5000 m with derating. The 12 kV impulse withstand (Uimp) covers transient overvoltages in solidly-grounded or impedance-grounded systems. ## Integration — panel footprint and mounting Fixed-mount design: the breaker sits on rails or a base plate. Dimensions are 997 mm wide × 352 mm high × 300 mm deep. Connection pitch is 230 mm between phases. The neutral pole is on the right (4P, right-side neutral). Control is push-button only — no electronic control unit is included, so you need the separate Micrologic trip unit (not part of this order code). Rear connections both top and bottom suit drawout-style switchgear cubicles where cabling enters from behind. ## Durability and dissipation Mechanical durability is 10 000 cycles with periodic preventive maintenance. Electrical endurance under AC-3 (motor switching) is 6000 cycles at 440/690 V. Maximum breaking time is 25 ms — fast enough to limit let-through energy in a high-fault-current scenario. Closing response time is 80 ms. Power dissipation at rated current is 650 W, which must be factored into switchgear ventilation calculations.","metaTitle":"Schneider Electric LV848196 MasterPact MTZ3 63 H1, 6300 A, 4","metaDescription":"Schneider Electric LV848196 MasterPact MTZ3 circuit breaker, 6300 A at 40 °C, 4P, fixed mount, H1 100 kA at 415 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"300 mm","Range":"MasterPacT","Width":"997 mm","title":"LV848196","Height":"352 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","description":"Circuit breaker MTZ3 63H1 - 6300 A - 4P fixed - right neutral - w/o Micrologic","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ3","Mounting mode":"Fixed","Sensor rating":"3200 A 4000 A 5000 A 6300 A","lifecycle_stage":"current","Connection pitch":"230 mm","Mounting support":"Rails Base plate","Neutral position":"Right","Performance type":"H1 100 kA 415 V AC","Pollution degree":"3 conforming to IEC 60947-1","Device short name":"MTZ3 63 H1","Poles description":"4P","Upside connection":"Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"6300 A at 40 °C","Downside connection":"Rear","Selectivity category":"Category B","Electrical durability":"AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3","Maximum breaking time":"25 ms","Mechanical durability":"10000 cycles with periodic preventive maintenance","Power dissipation in W":"650 W","IP degree of protection":"IP30 conforming to EN 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"80 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz 100 kA at 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 100 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 220 kA 500/525 V AC at 50/60 Hz 220 kA 660/690 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz 100 kA at 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f3c1c86e6ea3ba39a46c13f87140d338.pdf","sourceUrl":"https://www.se.com/ae/en/product/LV848196/circuit-breaker-mtz3-63h1-6300-a-4p-fixed-right-neutral-w-o-micrologic/"},"ai":{"faq":[{"question":"What is LV848196's rated current and breaking capacity?","answer":"Rated current is 6300 A at 40 °C. The H1 performance class gives 100 kA Icu/Ics at 415 V AC, and Icw is 100 kA for 3 seconds. Icm (making capacity) is 220 kA at 415 V."},{"question":"Where can I buy LV848196 and how is it quoted?","answer":"The LV848196 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does LV848196 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848196","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848196 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}