{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848240","canonicalUrl":"https://aoctrl.com/schneider/LV848240","factsUrl":"https://aoctrl.com/api/mcp/products/LV848240","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker Masterpact MTZ2 08L1, 800 A, 4P drawout, without Micrologic","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"Drawout circuit breaker with chassis: 15.9 in (403 mm) Drawout circuit breaker without chassis: 11.8 in (300 mm)","Range":"MasterPacT","Width":"Drawout circuit breaker with chassis: 21.9 in (556 mm) Drawout circuit breaker without chassis: 19.4 in (493 mm)","Height":"Drawout circuit breaker with chassis: 17.3 in (439 mm) Drawout circuit breaker without chassis: 11.8 in (300 mm)","Standards":"EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12","Control Type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact MTZ2","Mounting Mode":"Drawout","Sensor rating":"400 A 630 A 800 A","lifecycle_stage":"current","Connection pitch":"4.5 in (115 mm)","Mounting Support":"Rails Base plate","Neutral position":"Left","Performance type":"L1 150 kA 415 V AC","Pollution degree":"3 IEC 60947-1","Device short name":"MTZ2 08 L1","Poles description":"4P","Upside connection":"Front Rear","Device Application":"Power distribution protection","Line Rated Current":"800 A 104 °F (40 °C)","Operating altitude":"0...6561.68 ft (0...2000 m) without derating 2000...5000 m with derating","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"3000 cycles 690 V AC 50/60 Hz EN/IEC 60947-2 3000 cycles 440 V AC 50/60 Hz EN/IEC 60947-2","Maximum breaking time":"10 ms","Mechanical durability":"25000 cycles with periodic preventive maintenance","Nbr. of units in pkg.":"1","Power dissipation in W":"100 W","IP degree of protection":"IP30 conforming to EN 60529","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"150 kA 220/415 V AC 50/60 Hz 150 kA 440 V AC 50/60 Hz 130 kA 500/525 V AC 50/60 Hz 100 kA 660/690 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"30 kA 0.5 s 30 kA 1 s 30 kA 3 s","[Icm] rated short-circuit making capacity":"330 kA 220/415 V AC 50/60 Hz 330 kA 440 V AC 50/60 Hz 286 kA 500/525 V AC 50/60 Hz 220 kA 660/690 V AC 50/60 Hz","Integrated instantaneous protection (DIN in kA peak)":"72...88 kA","[Icu] rated ultimate short-circuit breaking capacity":"150 kA 220/415 V AC 50/60 Hz 150 kA 440 V AC 50/60 Hz 130 kA 500/525 V AC 50/60 Hz 100 kA 660/690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$24,228.64 – $25,440.08","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/90df4a4ca2ca21da14e853648d2873de.pdf","sourceUrl":"https://www.se.com/vn/en/product/LV848240/circuit-breaker-masterpact-mtz2-08l1-800-a-4p-drawout-without-micrologic/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848240/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}