{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848362","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848362","canonicalUrl":"https://aoctrl.com/schneider/LV848362","factsUrl":"https://aoctrl.com/api/mcp/products/LV848362","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MicroLogic 7.0 X electronic control unit, LV848362, LSIV protection, LCD display 128x96, drawout mount, 800-3200 A trip unit rating, Bluetooth 4.0 LE.","salesMarkdown":"The protection package is LSIV: long-time overload (ANSI 49), short-time short-circuit (ANSI 51), instantaneous short-circuit (ANSI 50), and earth-leakage (ANSI 51G). That's the full four-quadrant set — selectivity engineers will recognize the zone-selective interlocking (ZSI) built in, which lets multiple breakers in a cascade coordinate trip times without sacrificing speed on a close-in fault. It's a power meter too, not just a trip unit. Measures all three phase currents, neutral current IN RMS, ground fault current Ig RMS, phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power per phase and total, power factor, frequency, energy in/out/total, demand values, and harmonic distortion (THD) for current and voltage. Accuracy on current and voltage is ±0.5% for the main channels; active energy is ±1%. ## Communication and display — what you get without opening the panel The LV848362 has a 128×96 pixel LCD display on the front. That's enough to scroll through all metered values and protection settings without a laptop. For remote access, it talks Bluetooth 4.0 LE (30 kbit/s peer-to-peer), NFC (28,800 baud), and USB (115 kbaud). No Ethernet or Modbus on this variant — that's the domain of the MicroLogic X with communication modules. The Bluetooth range is short (peer-to-peer), so you stand near the breaker face to pair with a phone or tablet running Schneider's app. Data recording includes alarm logs, min/max of instantaneous values, data logs, maintenance logs, and event logs with time stamps. Thermal memory is on — so if the breaker trips on overload and you reclose hot, the trip curve accounts for the prior heat rise. That matters for motor feeders and high-inertia loads. This is a drawout-mounted control unit — it plugs into the MasterPacT breaker cradle. Indoor use only (pollution degree 3 per IEC 60947-1, overvoltage category IV per IEC 61010-1). Operating altitude up to 5000 m with voltage derating to 560 V AC. Relative humidity 95% at 55°C. Not approved for wet locations per IEC 61010-1, so keep it dry. Measurement voltage range is 208–828 V AC phase-to-phase, 120–480 V AC phase-to-neutral, 50/60 Hz. The rated operational voltage is 600 V AC ±10%. Frequency measurement range is 40–70 Hz. The protected poles configuration is flexible: 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, or 4P 3d + OSN. Neutral protection setting matches: 1 x Ir for 4P 4d, 0.5 x Ir for 4P 3d + N/2, 1.6 x Ir for 4P 3d + OSN, or no protection for 4P 3d. ## Standards and compliance — what the approvals mean The LV848362 carries EN/IEC 60947-2 (low-voltage switchgear and controlgear — circuit-breakers), EN/IEC 60947-1 (general rules), EN/IEC 60092-202 (marine electrical installations — switchgear and controlgear assemblies), EN/IEC 60255-1 (measuring relays and protection equipment), and EN/IEC 61010-1 (safety requirements for electrical equipment for measurement, control, and laboratory use). Measurement category IV per IEC 61010-2-30 — that's the highest category, for equipment installed at the origin of an installation (utility connection). EMC compliance includes electrostatic discharge, electromagnetic fields, fast transients, surge 1.2/50 µs, conducted RF, and conducted/radiated emissions Class A per CISPR 22.","metaTitle":"Schneider Electric LV848362 MicroLogic 7.0 X Control Unit, M","metaDescription":"Schneider Electric LV848362 MicroLogic 7.0 X electronic control unit for MasterPacT drawout breakers. LSIV protection, LCD display, Bluetooth/NFC/USB. Current production, sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Poles":"4P 3P","Range":"MasterPacT","title":"LV848362","Standards":"EN/IEC 60947-2 EN/IEC 60947-1 EN/IEC 60092-202 EN/IEC 60255-1 EN/IEC 61010-1","description":"MicroLogic 7.0X control unit, MasterPact MTZ2, drawout circuit breakers, LSIV protections","Display type":"LCD display - 128 x 96 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage","Mounting mode":"Drawout","Accuracy class":"Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)","Data recording":"Alarm logs Min/max of instantaneous values Data logs Maintenance logs Time stamping Event logs","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51 Earth-leakage protection conforming to ANSI 51G","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A","Device short name":"MicroLogic 7.0 X","Energy management":"Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Measurement voltage":"208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral","Type of measurement":"Power meter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Earth-leakage protection":"With","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer 28800 bauds conforming to ISO 15963 USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LSIV","[Ue] rated operational voltage":"600 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Instantaneous pick-up adjustment type Ii":"Adjustable","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app","[Ii] instantaneous pick-up adjustment range":"2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off","[Li Mode] Instantaneous Delay Adjustment Range":"0 ms in fast 20 ms in standard","Residual earth-leakage time delay adjustment type":"Adjustable","[IΔn] residual earth-leakage sensitive adjustment":"0.5...30 A adjustable in step of 0.1 A","[Δt] residual earth-leakage time delay adjustment":"60...800 ms resettable time 140...1000 ms break time"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,017.19 – $3,168.07","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aa0f29b8b1178a4af3c2823062d79c7b.pdf","sourceUrl":"https://www.se.com/au/en/product/LV848362/micrologic-7-0x-control-unit-masterpact-mtz2-drawout-circuit-breakers-lsiv-protections/"},"ai":{"faq":[{"question":"What is LV848362's listed poles (4P 3P) on this component line?","answer":"The LV848362 supports 4-pole and 3-pole configurations. The protected poles description includes 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN."},{"question":"What is LV848362's listed range (MasterPacT) on this component line?","answer":"The LV848362 belongs to the Schneider Electric MasterPacT range of low-voltage power circuit breakers and control units."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848362","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848362 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}