{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848362","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848362","canonicalUrl":"https://aoctrl.com/schneider/LV848362","factsUrl":"https://aoctrl.com/api/mcp/products/LV848362","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MicroLogic 7.0 X electronic control unit, LV848362, LSIV protection, LCD display 128x96, drawout mount, 800-3200 A trip unit rating, Bluetooth 4.0 LE.","salesMarkdown":"The protection package is LSIV: long-time overload (ANSI 49), short-time short-circuit (ANSI 51), instantaneous short-circuit (ANSI 50), and earth-leakage (ANSI 51G). That's the full four-quadrant set — selectivity engineers will recognize the zone-selective interlocking (ZSI) built in, which lets multiple breakers in a cascade coordinate trip times without sacrificing speed on a close-in fault. It's a power meter too, not just a trip unit. Measures all three phase currents, neutral current IN RMS, ground fault current Ig RMS, phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power per phase and total, power factor, frequency, energy in/out/total, demand values, and harmonic distortion (THD) for current and voltage. Accuracy on current and voltage is ±0.5% for the main channels; active energy is ±1%. ## Communication and display — what you get without opening the panel The LV848362 has a 128×96 pixel LCD display on the front. That's enough to scroll through all metered values and protection settings without a laptop. For remote access, it talks Bluetooth 4.0 LE (30 kbit/s peer-to-peer), NFC (28,800 baud), and USB (115 kbaud). No Ethernet or Modbus on this variant — that's the domain of the MicroLogic X with communication modules. The Bluetooth range is short (peer-to-peer), so you stand near the breaker face to pair with a phone or tablet running Schneider's app. Data recording includes alarm logs, min/max of instantaneous values, data logs, maintenance logs, and event logs with time stamps. Thermal memory is on — so if the breaker trips on overload and you reclose hot, the trip curve accounts for the prior heat rise. That matters for motor feeders and high-inertia loads. This is a drawout-mounted control unit — it plugs into the MasterPacT breaker cradle. Indoor use only (pollution degree 3 per IEC 60947-1, overvoltage category IV per IEC 61010-1). Operating altitude up to 5000 m with voltage derating to 560 V AC. Relative humidity 95% at 55°C. Not approved for wet locations per IEC 61010-1, so keep it dry. Measurement voltage range is 208–828 V AC phase-to-phase, 120–480 V AC phase-to-neutral, 50/60 Hz. The rated operational voltage is 600 V AC ±10%. Frequency measurement range is 40–70 Hz. The protected poles configuration is flexible: 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, or 4P 3d + OSN. Neutral protection setting matches: 1 x Ir for 4P 4d, 0.5 x Ir for 4P 3d + N/2, 1.6 x Ir for 4P 3d + OSN, or no protection for 4P 3d. ## Standards and compliance — what the approvals mean The LV848362 carries EN/IEC 60947-2 (low-voltage switchgear and controlgear — circuit-breakers), EN/IEC 60947-1 (general rules), EN/IEC 60092-202 (marine electrical installations — switchgear and controlgear assemblies), EN/IEC 60255-1 (measuring relays and protection equipment), and EN/IEC 61010-1 (safety requirements for electrical equipment for measurement, control, and laboratory use). Measurement category IV per IEC 61010-2-30 — that's the highest category, for equipment installed at the origin of an installation (utility connection). EMC compliance includes electrostatic discharge, electromagnetic fields, fast transients, surge 1.2/50 µs, conducted RF, and conducted/radiated emissions Class A per CISPR 22.","metaTitle":"Schneider Electric LV848362 MicroLogic 7.0 X Control Unit, M","metaDescription":"Schneider Electric LV848362 MicroLogic 7.0 X electronic control unit for MasterPacT drawout breakers. LSIV protection, LCD display, Bluetooth/NFC/USB. Current production, sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Poles":"4","Voltage":"600 V AC, +/- 10 %","Application":"Equipment protection, monitoring and control","Display Type":"LCD display - 128 x 96 pixels","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Main Product Or Component Type":"Control unit","Ambient Air Temperature Operation":"-25...70 °C (operating) -35 °C (for start-up of product)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,017.19 – $3,168.07","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aa0f29b8b1178a4af3c2823062d79c7b.pdf","sourceUrl":"https://www.se.com/au/en/product/LV848362/micrologic-7-0x-control-unit-masterpact-mtz2-drawout-circuit-breakers-lsiv-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848362/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848362","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848362 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}