{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848362WW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848362WW","canonicalUrl":"https://aoctrl.com/schneider/LV848362WW","factsUrl":"https://aoctrl.com/api/mcp/products/LV848362WW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MicroLogic 7.0 Xi electronic control unit, LV848362WW, drawout mount, 800-3200 A trip unit rating, LSIG protection, LCD display, full power metering, 600 VAC.","salesMarkdown":"## MicroLogic 7.0 Xi — what this control unit does The LV848362WW is a MicroLogic 7.0 Xi electronic control unit for MasterPacT drawout circuit breakers. It provides LSIG protection — overload (long-time), short-time, instantaneous short-circuit, and earth-leakage — plus full power metering on a 128 x 96 pixel LCD display. The trip unit rating spans 800 A to 3200 A, covering the MTZ1, MTZ2, and MTZ3 frame sizes. Rated operational voltage is 600 VAC. This is the metering-grade control unit for the MasterPacT range. It measures current per phase (I1, I2, I3, Iavg, IN RMS), voltage phase-to-phase and phase-to-neutral, active/reactive/apparent power and energy, power factor, frequency, THD for current and voltage, unbalance, and earth leakage current. Accuracy on current and voltage is ±0.5 %; active energy is ±1 %. Deployment context: this unit goes into a drawout MasterPacT breaker in a switchboard or motor control center. The LCD display gives local readout of all metered values without needing a separate power meter or HMI. ## Protection and metering in one package The MicroLogic 7.0 Xi combines LSIG protection with a Class 0.5 power meter. Protection functions include overload (long-time) per ANSI 49, instantaneous short-circuit per ANSI 50, short-time short-circuit per ANSI 51, and earth-leakage per ANSI 51G. Thermal memory is built in. Neutral protection is configurable: 1 x Ir for 4P 4d, 0.5 x Ir for 4P 3d + N/2, 1.6 x Ir for 4P 3d + OSN, or no protection for 4P 3d. Metering covers all standard electrical parameters: current, voltage, power, energy, power factor, frequency, THD, unbalance, and demand values. The LCD display shows 128 x 96 pixels — enough for one-line diagrams and real-time values. Data recording includes maintenance logs, min/max of instantaneous values, time stamping, data logs, event logs, and alarm logs. Communication is via USB peer-to-peer at 115 kbauds for local configuration and data download. The control unit is compatible with MasterPacT drawout breakers in 3P and 4P configurations, with protected poles options of 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN. The LV848362WW carries approvals to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60092-202 (marine), EN/IEC 60255-1, and EN/IEC 61010-1. Measurement category is IV per IEC 61010-2-30; overvoltage category is IV per IEC 61010-1. EMC compliance includes electrostatic discharge, electromagnetic fields, fast transients, surge 1.2/50 µs, conducted RF, and conducted/radiated emissions Class A per CISPR 22. Operating altitude is up to 5000 m with voltage derating to 560 VAC. Relative humidity tolerance is 95 % at 55 °C per IEC 60068-2-30. Network frequency is 50/60 Hz; frequency measurement range is 40 to 70 Hz. Measurement voltage range is 208 to 828 VAC phase-to-phase and 120 to 480 VAC phase-to-neutral.","metaTitle":"LV848362WW MicroLogic 7.0 Xi Control Unit, MasterPacT, 800-3","metaDescription":"LV848362WW MicroLogic 7.0 Xi electronic control unit for MasterPacT drawout breakers. LSIG protection, full power metering, LCD display. Current lifecycle stage, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Poles":"3P 4P","Range":"MasterPacT","Standards":"EN/IEC 60947-1 EN/IEC 60092-202 EN/IEC 60255-1 EN/IEC 60947-2 EN/IEC 61010-1","Control type":"Wired control","Display type":"LCD display - 128 x 96 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage","Mounting mode":"Drawout","Accuracy class":"Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)","Data recording":"Maintenance logs Min/max of instantaneous values Time stamping Data logs Event logs Alarm logs","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51 Earth-leakage protection conforming to ANSI 51G","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A","Device short name":"MicroLogic 7.0 Xi","Energy management":"Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Measurement voltage":"208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral","Type of measurement":"Power meter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Earth-leakage protection":"With","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LSIV","[Ue] rated operational voltage":"600 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Instantaneous pick-up adjustment type Ii":"Adjustable","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app","[Ii] instantaneous pick-up adjustment range":"2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off","[Li Mode] Instantaneous Delay Adjustment Range":"0 ms in fast 20 ms in standard","Residual earth-leakage time delay adjustment type":"Adjustable","[IΔn] residual earth-leakage sensitive adjustment":"0.5...30 A adjustable in step of 0.1 A","[Δt] residual earth-leakage time delay adjustment":"60...800 ms resettable time 140...1000 ms break time"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/15661bf9def5117c2d90861bce350dc5.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848362WW/micrologic-7-0xi-control-unit-no-wireless-masterpact-mtz2-drawout-circuit-breakers-lsiv-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848362WW/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative to LV848362WW in this component family?","answer":"Within the MicroLogic family, the 7.0 Xi is the metering-grade control unit. The 6.0 E is the standard electronic trip unit without metering; the 5.0 A is the basic amp-meter version. All share the same drawout mounting and frame compatibility for MasterPacT breakers, but the 7.0 Xi is the only one with full power metering and LCD display."},{"question":"What is LV848362WW's listed poles (3P 4P) on this component line?","answer":"The LV848362WW control unit supports both 3-pole and 4-pole MasterPacT drawout breakers, with protected pole configurations of 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN."},{"question":"What compliance documentation does this brand provide for LV848362WW (RoHS, REACH, UL, IEC)?","answer":"The LV848362WW is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60092-202 (marine), EN/IEC 60255-1, and EN/IEC 61010-1. It carries measurement category IV and overvoltage category IV ratings. EMC compliance is per CISPR 22 Class A. RoHS and REACH documentation is available from the manufacturer upon request."},{"question":"How do I get current pricing and availability for LV848362WW?","answer":"The LV848362WW is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848362WW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848362WW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}